Effect of balloon guide catheter on clinical outcomes and reperfusion in Trevo thrombectomy. (2nd February 2019)
- Record Type:
- Journal Article
- Title:
- Effect of balloon guide catheter on clinical outcomes and reperfusion in Trevo thrombectomy. (2nd February 2019)
- Main Title:
- Effect of balloon guide catheter on clinical outcomes and reperfusion in Trevo thrombectomy
- Authors:
- Nguyen, Thanh N
Castonguay, Alicia C
Nogueira, Raul G
Haussen, Diogo C
English, Joey D
Satti, Sudhakar R
Chen, Jennifer
Farid, Hamed
Borders, Candace
Veznedaroglu, Erol
Binning, Mandy J
Puri, Ajit S
Vora, Nirav A
Budzik, Ron F
Dabus, Guilherme
Linfante, Italo
Janardhan, Vallabh
Alshekhlee, Amer
Abraham, Michael G
Edgell, Randall C
Taqi, M Asif
El Khoury, Ramy
Mokin, Maxim
Majjhoo, Aniel Q
Kabbani, Mouhammed R
Froehler, Michael T
Finch, Ira
Ansari, Sameer A
Novakovic, Roberta
Abdalkader, Mohamad
Zaidat, Osama O
… (more) - Abstract:
- Abstract : Introduction: The Solitaire stent retriever registry showed improved reperfusion, faster procedure times, and better outcome in acute stroke patients with large vessel occlusion treated with a balloon guide catheter (BGC) and Solitaire stent retriever compared with a conventional guide catheter. The goal of this study was to evaluate whether use of a BGC with the Trevo stent retriever improves outcomes compared with a conventional guide catheter. Methods: The TRACK registry recruited 23 sites to submit demographic, clinical, and site adjudicated angiographic and outcome data on consecutive patients treated with the Trevo stent retriever. BGC use was at the discretion of the physician. Results: 536 anterior circulation patients (of whom 279 (52.1%) had BGC placement) were included in this analysis. Baseline characteristics were notable for younger patients in the BGC group (65.4±15.3 vs 68.1±13.6, P=0.03) and lower rate of hypertension (72% vs 79%, P=0.06). Mean time from symptom onset to groin puncture was longer in the BGC group (357 vs 319 min, P=0.06).Thrombolysis in Cerebral Infarction 2b/3 scores were higher in the BGC cohort (84% vs 75.5%, P=0.01). There was no difference in reperfusion time, first pass effect, number of passes, or rescue therapy. Good clinical outcome at 3 months was superior in patients with BGC (57% vs 40%; P=0.0004) with a lower mortality rate (13% vs 23%, P=0.008). Multivariate analysis demonstrated that BGC use was an independentAbstract : Introduction: The Solitaire stent retriever registry showed improved reperfusion, faster procedure times, and better outcome in acute stroke patients with large vessel occlusion treated with a balloon guide catheter (BGC) and Solitaire stent retriever compared with a conventional guide catheter. The goal of this study was to evaluate whether use of a BGC with the Trevo stent retriever improves outcomes compared with a conventional guide catheter. Methods: The TRACK registry recruited 23 sites to submit demographic, clinical, and site adjudicated angiographic and outcome data on consecutive patients treated with the Trevo stent retriever. BGC use was at the discretion of the physician. Results: 536 anterior circulation patients (of whom 279 (52.1%) had BGC placement) were included in this analysis. Baseline characteristics were notable for younger patients in the BGC group (65.4±15.3 vs 68.1±13.6, P=0.03) and lower rate of hypertension (72% vs 79%, P=0.06). Mean time from symptom onset to groin puncture was longer in the BGC group (357 vs 319 min, P=0.06).Thrombolysis in Cerebral Infarction 2b/3 scores were higher in the BGC cohort (84% vs 75.5%, P=0.01). There was no difference in reperfusion time, first pass effect, number of passes, or rescue therapy. Good clinical outcome at 3 months was superior in patients with BGC (57% vs 40%; P=0.0004) with a lower mortality rate (13% vs 23%, P=0.008). Multivariate analysis demonstrated that BGC use was an independent predictor of good clinical outcome (OR 2; 95% CI 1.3 to 3.1, P=0.001). Conclusions: In acute stroke patients presenting with anterior circulation large vessel occlusion, use of a BGC with the Trevo stent retriever resulted in improved reperfusion, improved clinical outcome, and lower mortality. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 11:Number 9(2019)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 11:Number 9(2019)
- Issue Display:
- Volume 11, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 9
- Issue Sort Value:
- 2019-0011-0009-0000
- Page Start:
- 861
- Page End:
- 865
- Publication Date:
- 2019-02-02
- Subjects:
- stroke -- thrombectomy -- technique -- balloon -- catheter
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2018-014452 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17895.xml