Time resolved fluorometric immunoassay, using europium labelled antihuman IgG, for the detection of human tetanus antitoxin in serum. Issue 10 (1st October 2001)
- Record Type:
- Journal Article
- Title:
- Time resolved fluorometric immunoassay, using europium labelled antihuman IgG, for the detection of human tetanus antitoxin in serum. Issue 10 (1st October 2001)
- Main Title:
- Time resolved fluorometric immunoassay, using europium labelled antihuman IgG, for the detection of human tetanus antitoxin in serum
- Authors:
- Maple, P A C
Jones, C S
Andrews, N J - Abstract:
- Abstract : A time resolved fluorometric immunoassay (TRFIA) has been developed and compared with an in house enzyme linked immunosorbent assay (ELISA) and commercial ELISA (Bindazyme) for the detection of tetanus antitoxin in human sera. A panel of 132 sera submitted for routine testing was used. Scatterplots showed a high degree of correlation between all three assays, although some divergence of results was apparent for low titre sera when comparing in house ELISA results with Bindazyme ELISA and TRFIA results. The TRFIA appeared to be more sensitive than the in house ELISA, and the Bindazyme assay compared well with the TRFIA. The intra-assay precision of all three assays, in terms of percentage coefficient of variation (%CV), was between 2.0% and 4.0%. The interassay precision ranged from 5% to 8% for the in house ELISA, 13% to 19% for the Bindazyme assay, and 11% to 13% for TRFIA. Both Bindazyme and TRFIA assays were simple to perform, accurate, reproducible, and amenable to automation. A particular benefit of the TRFIA was its large dynamic range, enabling tetanus antitoxin values of 0.01 IU/ml to 50 IU/ml to be measured with just one dilution of serum. TRFIA appears to be a useful serological technique worthy of further development.
- Is Part Of:
- Journal of clinical pathology. Volume 54:Issue 10(2001)
- Journal:
- Journal of clinical pathology
- Issue:
- Volume 54:Issue 10(2001)
- Issue Display:
- Volume 54, Issue 10 (2001)
- Year:
- 2001
- Volume:
- 54
- Issue:
- 10
- Issue Sort Value:
- 2001-0054-0010-0000
- Page Start:
- 812
- Page End:
- 815
- Publication Date:
- 2001-10-01
- Subjects:
- tetanus antitoxin -- fluorometric immunoassay -- enzyme linked immunoassay
Pathology -- Periodicals
Pathology, Molecular -- Periodicals
616.0705 - Journal URLs:
- http://jcp.bmjjournals.com ↗
http://jcp.bmjjournals.com/content/by/year ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=162&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- ↗
- Languages:
- English
- ISSNs:
- 0021-9746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17898.xml