4D DSA a new technique for arteriovenous malformation evaluation: a feasibility study. (12th January 2015)
- Record Type:
- Journal Article
- Title:
- 4D DSA a new technique for arteriovenous malformation evaluation: a feasibility study. (12th January 2015)
- Main Title:
- 4D DSA a new technique for arteriovenous malformation evaluation: a feasibility study
- Authors:
- Sandoval-Garcia, Carolina
Royalty, Kevin
Yang, Pengfei
Niemann, David
Ahmed, Azam
Aagaard-Kienitz, Beverly
Başkaya, Mustafa K
Schafer, Sebastian
Strother, Charles - Abstract:
- Abstract : Background: The angioarchitectural features of an arteriovenous malformation (AVM) provide key information regarding natural history and treatment planning. Because of rapid filling and vascular overlap, two-dimensional (2D) and three-dimensional (3D) digital subtraction angiography (DSA) are often suboptimal for evaluation of these features. We have developed an algorithm that derives a series of fully time-resolved 3D DSA volumes (four-dimensional (4D) DSA) at up to 30 frames/s from a conventional 3D DSA. The temporal/spatial resolution of 4D reconstructions is significantly higher than that provided by current MR angiography and CT angiography techniques. 4D reconstruction allows viewing of an AVM from any angle at any time during its opacification. This feasibility study investigated the potential of 4D DSA to improve the ability to analyze angioarchitectural features compared with conventional 2D and 3D DSA. Methods: 2D, 3D, and 4D DSA reconstructions of angiographic studies of six AVMs were evaluated by three cerebrovascular neurosurgeons and one interventional neuroradiologist. These observers evaluated the ability of each modality to visualize the angioarchitectural features of the AVMs. They also compared the information provided using the combination of 2D and 3D DSA with that provided by a 4D DSA reconstruction. Results: By consensus, 4D DSA provided the best ability to visualize the internal features of the AVM including intranidal aneurysms, fistulae,Abstract : Background: The angioarchitectural features of an arteriovenous malformation (AVM) provide key information regarding natural history and treatment planning. Because of rapid filling and vascular overlap, two-dimensional (2D) and three-dimensional (3D) digital subtraction angiography (DSA) are often suboptimal for evaluation of these features. We have developed an algorithm that derives a series of fully time-resolved 3D DSA volumes (four-dimensional (4D) DSA) at up to 30 frames/s from a conventional 3D DSA. The temporal/spatial resolution of 4D reconstructions is significantly higher than that provided by current MR angiography and CT angiography techniques. 4D reconstruction allows viewing of an AVM from any angle at any time during its opacification. This feasibility study investigated the potential of 4D DSA to improve the ability to analyze angioarchitectural features compared with conventional 2D and 3D DSA. Methods: 2D, 3D, and 4D DSA reconstructions of angiographic studies of six AVMs were evaluated by three cerebrovascular neurosurgeons and one interventional neuroradiologist. These observers evaluated the ability of each modality to visualize the angioarchitectural features of the AVMs. They also compared the information provided using the combination of 2D and 3D DSA with that provided by a 4D DSA reconstruction. Results: By consensus, 4D DSA provided the best ability to visualize the internal features of the AVM including intranidal aneurysms, fistulae, venous obstructions, and sequence of filling and draining. 2D and 3D images in comparison were limited because of overlap of the vasculature. Conclusions: In this small series, 4D DSA provided better ability to visualize the angioarchitecture of an AVM than conventional methods. Further experience is required to determine the ultimate utility of this technique. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 8:Number 3(2016)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 8:Number 3(2016)
- Issue Display:
- Volume 8, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 3
- Issue Sort Value:
- 2016-0008-0003-0000
- Page Start:
- 300
- Page End:
- 304
- Publication Date:
- 2015-01-12
- Subjects:
- Arteriovenous Malformation -- Angiography -- Technique -- Vascular Malformation
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2014-011534 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17896.xml