Evaluation of keratoconus progression. Issue 4 (1st June 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of keratoconus progression. Issue 4 (1st June 2018)
- Main Title:
- Evaluation of keratoconus progression
- Authors:
- Shajari, Mehdi
Steinwender, Gernot
Herrmann, Kim
Kubiak, Kate Barbara
Pavlovic, Ivana
Plawetzki, Elena
Schmack, Ingo
Kohnen, Thomas - Abstract:
- Abstract : Aim: To define variables for the evaluation of keratoconus progression and to determine cut-off values. Methods: In this retrospective cohort study (2010–2016), 265 eyes of 165 patients diagnosed with keratoconus underwent two Scheimpflug measurements (Pentacam) that took place 1 year apart ±3 months. Variables used for keratoconus detection were evaluated for progression and a correlation analysis was performed. By logistic regression analysis, a keratoconus progression index (KPI) was defined. Receiver-operating characteristic curve (ROC) analysis was performed and Youden Index calculated to determine cut-off values. Results: Variables used for keratoconus detection showed a weak correlation with each other (eg, correlation r=0.245 between RPImin and Kmax, p<0.001). Therefore, we used parameters that took several variables into consideration (eg, D-index, index of surface variance, index for height asymmetry, KPI). KPI was defined by logistic regression and consisted of a Pachymin coefficient of −0.78 (p=0.001), a maximum elevation of back surface coefficient of 0.27 and coefficient of corneal curvature at the zone 3 mm away from the thinnest point on the posterior corneal surface of −12.44 (both p<0.001). The two variables with the highest Youden Index in the ROC analysis were D-index and KPI: D-index had a cut-off of 0.4175 (70.6% sensitivity) and Youden Index of 0.606. Cut-off for KPI was −0.78196 (84.7% sensitivity) and a Youden Index of 0.747; both 90%Abstract : Aim: To define variables for the evaluation of keratoconus progression and to determine cut-off values. Methods: In this retrospective cohort study (2010–2016), 265 eyes of 165 patients diagnosed with keratoconus underwent two Scheimpflug measurements (Pentacam) that took place 1 year apart ±3 months. Variables used for keratoconus detection were evaluated for progression and a correlation analysis was performed. By logistic regression analysis, a keratoconus progression index (KPI) was defined. Receiver-operating characteristic curve (ROC) analysis was performed and Youden Index calculated to determine cut-off values. Results: Variables used for keratoconus detection showed a weak correlation with each other (eg, correlation r=0.245 between RPImin and Kmax, p<0.001). Therefore, we used parameters that took several variables into consideration (eg, D-index, index of surface variance, index for height asymmetry, KPI). KPI was defined by logistic regression and consisted of a Pachymin coefficient of −0.78 (p=0.001), a maximum elevation of back surface coefficient of 0.27 and coefficient of corneal curvature at the zone 3 mm away from the thinnest point on the posterior corneal surface of −12.44 (both p<0.001). The two variables with the highest Youden Index in the ROC analysis were D-index and KPI: D-index had a cut-off of 0.4175 (70.6% sensitivity) and Youden Index of 0.606. Cut-off for KPI was −0.78196 (84.7% sensitivity) and a Youden Index of 0.747; both 90% specificity. Conclusions: Keratoconus progression should be defined by evaluating parameters that consider several corneal changes; we suggest D-index and KPI to detect progression. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 103:Issue 4(2019)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 103:Issue 4(2019)
- Issue Display:
- Volume 103, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 103
- Issue:
- 4
- Issue Sort Value:
- 2019-0103-0004-0000
- Page Start:
- 551
- Page End:
- 557
- Publication Date:
- 2018-06-01
- Subjects:
- Cornea
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2017-311651 ↗