Treatment of severe chronic ocular graft-versus-host disease using 100% autologous serum eye drops from a sealed manufacturing system: a retrospective cohort study. Issue 3 (6th June 2016)
- Record Type:
- Journal Article
- Title:
- Treatment of severe chronic ocular graft-versus-host disease using 100% autologous serum eye drops from a sealed manufacturing system: a retrospective cohort study. Issue 3 (6th June 2016)
- Main Title:
- Treatment of severe chronic ocular graft-versus-host disease using 100% autologous serum eye drops from a sealed manufacturing system: a retrospective cohort study
- Authors:
- Tahmaz, Volkan
Gehlsen, Uta
Sauerbier, Laura
Holtick, Udo
Engel, Lisa
Radojska, Stela
Petrescu-Jipa, Viorica-Maria
Scheid, Christof
Hallek, Michael
Gathof, Birgit
Cursiefen, Claus
Steven, Philipp - Abstract:
- Abstract : Background/Aims: To analyse patients with chronic ocular graft-versus-host disease (GvHD) under treatment with 100% autologous serum eye drops from a sealed manufacturing system. Methods: 17 patients with chronic ocular GvHD received 100% autologous serum eye drops from single use vials manufactured in a sealed system. Retrospective analysis included visual acuity, corneal staining, frequency of artificial tears, ocular symptoms by means of a questionnaire and information on subjective side effects and cost compensation. Results: Data of prior to autologous serum eye drops therapy and at a 6-month follow-up were obtained. They demonstrated a significant increase in visual acuity (logMAR oculus dexter/right eye (OD) 0.5±0.32 to 0.4±0.3; oculus sinister/left eye (OS) 0.6±0.35 to 0.3±0.35; p=0.177/0.003) and significant improvement in corneal staining (Oxford grading scheme: OD from 3±1.03 to 2±1.43, OS from 4±1.0 to 2±1.09, p=0.004/0.001) and ocular symptoms (ocular surface disease index: 88±20.59 to 63±22.77; p=0.02). Frequency of artificial tears was reduced and no side effects were reported. Patient satisfaction was 100%, and cost compensation by health insurance reached 80%. Conclusions: 100% autologous serum eye drops using a sealed manufacturing system were efficient in improving the ocular surface, patient symptoms and visual acuity without side effects. It seems to be safe to use 100% autologous serum despite earlier suspicions regarding immune complexAbstract : Background/Aims: To analyse patients with chronic ocular graft-versus-host disease (GvHD) under treatment with 100% autologous serum eye drops from a sealed manufacturing system. Methods: 17 patients with chronic ocular GvHD received 100% autologous serum eye drops from single use vials manufactured in a sealed system. Retrospective analysis included visual acuity, corneal staining, frequency of artificial tears, ocular symptoms by means of a questionnaire and information on subjective side effects and cost compensation. Results: Data of prior to autologous serum eye drops therapy and at a 6-month follow-up were obtained. They demonstrated a significant increase in visual acuity (logMAR oculus dexter/right eye (OD) 0.5±0.32 to 0.4±0.3; oculus sinister/left eye (OS) 0.6±0.35 to 0.3±0.35; p=0.177/0.003) and significant improvement in corneal staining (Oxford grading scheme: OD from 3±1.03 to 2±1.43, OS from 4±1.0 to 2±1.09, p=0.004/0.001) and ocular symptoms (ocular surface disease index: 88±20.59 to 63±22.77; p=0.02). Frequency of artificial tears was reduced and no side effects were reported. Patient satisfaction was 100%, and cost compensation by health insurance reached 80%. Conclusions: 100% autologous serum eye drops using a sealed manufacturing system were efficient in improving the ocular surface, patient symptoms and visual acuity without side effects. It seems to be safe to use 100% autologous serum despite earlier suspicions regarding immune complex accumulations and exacerbation of ocular surface inflammation. The potential effects of serum levels of systemic immunosuppressives through readministration onto the ocular surface need to be elucidated. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 101:Issue 3(2017)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 101:Issue 3(2017)
- Issue Display:
- Volume 101, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 101
- Issue:
- 3
- Issue Sort Value:
- 2017-0101-0003-0000
- Page Start:
- 322
- Page End:
- 326
- Publication Date:
- 2016-06-06
- Subjects:
- Cornea -- Inflammation -- Treatment Medical -- Wound healing
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2015-307666 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17897.xml