Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experience. (17th September 2014)
- Record Type:
- Journal Article
- Title:
- Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experience. (17th September 2014)
- Main Title:
- Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experience
- Authors:
- Lin, Ning
Brouillard, Adam M
Keigher, Kiffon M
Lopes, Demetrius K
Binning, Mandy J
Liebman, Kenneth M
Veznedaroglu, Erol
Magarik, Jordan A
Mocco, J
Duckworth, Edward A
Arthur, Adam S
Ringer, Andrew J
Snyder, Kenneth V
Levy, Elad I
Siddiqui, Adnan H - Abstract:
- Abstract : Objective: Utilization of the Pipeline embolization device (PED) in complex ruptured aneurysms has not been well studied. We evaluated the safety and effectiveness data from five participating US centers. Methods: Records of patients with ruptured cerebral aneurysms who underwent PED treatment between 2011 and 2013 were retrospectively reviewed. Results: 26 patients with ruptured aneurysms underwent PED treatment (mean age 51.4±13.2 years;16 women). At presentation, 8 patients (30.8%) had a Hunt–Hess grade of IV or above; 11 required extraventricular drain placement. Aneurysm morphologies were: 8 dissecting, 8 blister-like, 6 fusiform, and 4 saccular. There were 22 anterior circulation and 4 posterior circulation aneurysms. PED deployment was successful in all patients, with adjunctive coiling utilized in 12. Periprocedural complications occurred in 5 (19.2%), including 3 inhospital deaths. 23 patients (88.5%) had postoperative angiography at a mean of 5.9 months: 18 aneurysms (78.3%) were completely occluded, 3 (13.0%) had residual neck filling, and 2 (8.7%) had residual dome filling. All blister-type aneurysms were completely occluded at follow-up. Clinical follow-up was available for an average of 10.1 months (range 2–21 months), with one asymptomatic in-stent stenosis and one asymptomatic thromboembolic stroke noted. Good outcome (modified Rankin Scale (mRS) score of 0–2) was achieved in 20 patients (76.9%), fair (mRS 3–4) in 3 (11.5%), and 3 died (11.5%).Abstract : Objective: Utilization of the Pipeline embolization device (PED) in complex ruptured aneurysms has not been well studied. We evaluated the safety and effectiveness data from five participating US centers. Methods: Records of patients with ruptured cerebral aneurysms who underwent PED treatment between 2011 and 2013 were retrospectively reviewed. Results: 26 patients with ruptured aneurysms underwent PED treatment (mean age 51.4±13.2 years;16 women). At presentation, 8 patients (30.8%) had a Hunt–Hess grade of IV or above; 11 required extraventricular drain placement. Aneurysm morphologies were: 8 dissecting, 8 blister-like, 6 fusiform, and 4 saccular. There were 22 anterior circulation and 4 posterior circulation aneurysms. PED deployment was successful in all patients, with adjunctive coiling utilized in 12. Periprocedural complications occurred in 5 (19.2%), including 3 inhospital deaths. 23 patients (88.5%) had postoperative angiography at a mean of 5.9 months: 18 aneurysms (78.3%) were completely occluded, 3 (13.0%) had residual neck filling, and 2 (8.7%) had residual dome filling. All blister-type aneurysms were completely occluded at follow-up. Clinical follow-up was available for an average of 10.1 months (range 2–21 months), with one asymptomatic in-stent stenosis and one asymptomatic thromboembolic stroke noted. Good outcome (modified Rankin Scale (mRS) score of 0–2) was achieved in 20 patients (76.9%), fair (mRS 3–4) in 3 (11.5%), and 3 died (11.5%). Conclusions: The PED can be utilized for ruptured aneurysms and is a good option for blister-type aneurysms. However, due to periprocedural complications, it should be reserved for lesions that are difficult to treat by conventional clipping or coiling. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 7:Number 11(2015)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 7:Number 11(2015)
- Issue Display:
- Volume 7, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 7
- Issue:
- 11
- Issue Sort Value:
- 2015-0007-0011-0000
- Page Start:
- 808
- Page End:
- 815
- Publication Date:
- 2014-09-17
- Subjects:
- Aneurysm -- Hemorrhage -- Flow Diverter
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2014-011320 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17897.xml