Comparison of structure–function relationship between corresponding retinal nerve fibre layer thickness and Octopus visual field cluster defect values determined by normal and tendency-oriented strategies. Issue 2 (22nd April 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of structure–function relationship between corresponding retinal nerve fibre layer thickness and Octopus visual field cluster defect values determined by normal and tendency-oriented strategies. Issue 2 (22nd April 2016)
- Main Title:
- Comparison of structure–function relationship between corresponding retinal nerve fibre layer thickness and Octopus visual field cluster defect values determined by normal and tendency-oriented strategies
- Authors:
- Holló, Gábor
- Abstract:
- Abstract : Background/aims: Previously, we found a strong structure–function relationship between Octopus visual field cluster sensitivity and corresponding sector retinal nerve fibre layer thickness (RNFLT) values, using normal strategy and 16 custom-made cluster–sector pairs. However, Octopus commercially offers 10 clusters, correction for diffuse defect (corrected clusters) and tendency-oriented perimetry (TOP) strategy. In the current investigation, we evaluated structure–function relationship for these conditions, respectively. Methods: Twenty-four healthy, 45 ocular hypertensive and 63 glaucoma eyes underwent Octopus perimetry (normal and TOP strategies) and RNFLT measurements on the same day. Pearson's correlation between corresponding cluster defect and sector RNFLT values was investigated. Results: Correlation between the corresponding cluster defect and sector RNFLT values was significant (p<0.0001) for all clusters, with both test strategies. The r values ranged from −0.3529 and −0.3877 to −0.5798 and −0.5893, respectively. The highest r values were found for the inferotemporal RNFLT sector superior and superior paracentral cluster pairs with both strategies. No difference in correlation was seen between the strategies (p≥0.183). For corrected clusters, significant correlation (p<0.01) was seen only for two inferotemporal and one superotemporal RNFLT sectors, with both strategies (r values: −0.2446, −0.2375; −0.3526, −0.3119; −0.2392, −0.2340, respectively).Abstract : Background/aims: Previously, we found a strong structure–function relationship between Octopus visual field cluster sensitivity and corresponding sector retinal nerve fibre layer thickness (RNFLT) values, using normal strategy and 16 custom-made cluster–sector pairs. However, Octopus commercially offers 10 clusters, correction for diffuse defect (corrected clusters) and tendency-oriented perimetry (TOP) strategy. In the current investigation, we evaluated structure–function relationship for these conditions, respectively. Methods: Twenty-four healthy, 45 ocular hypertensive and 63 glaucoma eyes underwent Octopus perimetry (normal and TOP strategies) and RNFLT measurements on the same day. Pearson's correlation between corresponding cluster defect and sector RNFLT values was investigated. Results: Correlation between the corresponding cluster defect and sector RNFLT values was significant (p<0.0001) for all clusters, with both test strategies. The r values ranged from −0.3529 and −0.3877 to −0.5798 and −0.5893, respectively. The highest r values were found for the inferotemporal RNFLT sector superior and superior paracentral cluster pairs with both strategies. No difference in correlation was seen between the strategies (p≥0.183). For corrected clusters, significant correlation (p<0.01) was seen only for two inferotemporal and one superotemporal RNFLT sectors, with both strategies (r values: −0.2446, −0.2375; −0.3526, −0.3119; −0.2392, −0.2340, respectively). Conclusions: Octopus normal and TOP strategies provide similar, moderate-to-strong negative correlation between the corresponding cluster defect and sector RNFLT values for all 10 manufacturer-provided clusters. For corrected clusters the relationship is poor, which suggests that by correcting for diffuse sensitivity loss some local glaucomatous defect is removed. For structure-function based clinical decisions, use of TOP is possible but use of corrected clusters is not recommended. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 101:Issue 2(2017)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 101:Issue 2(2017)
- Issue Display:
- Volume 101, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 101
- Issue:
- 2
- Issue Sort Value:
- 2017-0101-0002-0000
- Page Start:
- 150
- Page End:
- 154
- Publication Date:
- 2016-04-22
- Subjects:
- Glaucoma
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2015-307759 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17901.xml