Method of LDL Cholesterol Measurement Influences Classification of LDL Cholesterol Treatment Goals: Clinical Research Study. (1st December 2010)
- Record Type:
- Journal Article
- Title:
- Method of LDL Cholesterol Measurement Influences Classification of LDL Cholesterol Treatment Goals: Clinical Research Study. (1st December 2010)
- Main Title:
- Method of LDL Cholesterol Measurement Influences Classification of LDL Cholesterol Treatment Goals
- Authors:
- Agrawal, Mayank
Spencer, Horace J.
Faas, Fred H. - Abstract:
- Abstract : Background: Low-density lipoprotein cholesterol (LDL-C) has been clearly associated with the risk of developing coronary heart disease. The best and most convenient method for determining LDL-C has come under increased scrutiny in recent years. We present comparisons of the Friedewald calculated LDL-C (C-LDL-C) and direct LDL-C (D-LDL-C) using 3 different homogenous assays. This highlights differences between the 2 methods of LDL-C measurement and how this affects the classification of samples into different LDL-C treatment goals as determined by the National Cholesterol Education Program Adult Treatment Panel III guidelines thus potentially affecting treatment strategies. Methods: Lipid profiles of a total of 2208 clinic patients were retrieved from the Central Arkansas VA Healthcare System clinical laboratory database. Samples studied were of 1-week period during the 3 periods studied: 2000 (period 1), 2002 (period 2), and 2005 (period 3). Different homogenous assays for D-LDL-C measurement were used for each of the 3 periods. Results: There is a fundamental disagreement between D-LDL-C and C-LDL-C, although Pearson correlation coefficients are 0.93, 0.97, and 0.98 for periods 1, 2, and 3, respectively. Using the model for period 1, when C-LDL-C is 70 mg/dL, the predicted D-LDL-C is 95 mg/dL (36% higher). The differences between C-LDL-C and predicted D-LDL-C progressively decrease at higher LDL-C cut points. In the assay used in period 3, there are 290 samplesAbstract : Background: Low-density lipoprotein cholesterol (LDL-C) has been clearly associated with the risk of developing coronary heart disease. The best and most convenient method for determining LDL-C has come under increased scrutiny in recent years. We present comparisons of the Friedewald calculated LDL-C (C-LDL-C) and direct LDL-C (D-LDL-C) using 3 different homogenous assays. This highlights differences between the 2 methods of LDL-C measurement and how this affects the classification of samples into different LDL-C treatment goals as determined by the National Cholesterol Education Program Adult Treatment Panel III guidelines thus potentially affecting treatment strategies. Methods: Lipid profiles of a total of 2208 clinic patients were retrieved from the Central Arkansas VA Healthcare System clinical laboratory database. Samples studied were of 1-week period during the 3 periods studied: 2000 (period 1), 2002 (period 2), and 2005 (period 3). Different homogenous assays for D-LDL-C measurement were used for each of the 3 periods. Results: There is a fundamental disagreement between D-LDL-C and C-LDL-C, although Pearson correlation coefficients are 0.93, 0.97, and 0.98 for periods 1, 2, and 3, respectively. Using the model for period 1, when C-LDL-C is 70 mg/dL, the predicted D-LDL-C is 95 mg/dL (36% higher). The differences between C-LDL-C and predicted D-LDL-C progressively decrease at higher LDL-C cut points. In the assay used in period 3, there are 290 samples with D-LDL-C values between 100 and 130 mg/dL. Of these, only 182 samples show agreement with C-LDL-C values, whereas 90 samples with a D-LDL-C in the 100- to 130-mg/dL range are in the 70- to 100-mg/dL range using the C-LDL-C assay. Although the κ statistics suggests the LDL-C measures have relatively high levels of agreement, the significant generalized McNemar tests ( P < 0.01) provide additional evidence of disagreement between C-LDL-C and D-LDL-C during all the 3 periods. Conclusions: Our results highlight D-LDL-C measurements using 3 different assays during 3 different periods. In all assays, there is a substantial lack of agreement between D-LDL-C and C-LDL-C, which, in most cases, resulted in higher D-LDL-C values than C-LDL-C. This leads to clinically significant misclassification of patient's LDL-C to a different LDL-C treatment goal, which would potentially result in more drug usage, thus exposing patients to more potential adverse effects and at a much greater cost with little evidence of benefit. … (more)
- Is Part Of:
- Journal of investigative medicine. Volume 58:Number 8(2010)
- Journal:
- Journal of investigative medicine
- Issue:
- Volume 58:Number 8(2010)
- Issue Display:
- Volume 58, Issue 8 (2010)
- Year:
- 2010
- Volume:
- 58
- Issue:
- 8
- Issue Sort Value:
- 2010-0058-0008-0000
- Page Start:
- 945
- Page End:
- 949
- Publication Date:
- 2010-12-01
- Subjects:
- direct LDL -- calculated LDL -- cholesterol
Clinical medicine -- Periodicals
Medicine -- Research -- Periodicals
Medicine
Research -- United States
Clinical medicine
Medicine -- Research
Periodicals
616.075 - Journal URLs:
- http://journals.lww.com/jinvestigativemed/pages/default.aspx ↗
http://jim.bmj.com/ ↗
https://journals.sagepub.com/home/IMJ ↗
http://journals.lww.com ↗ - DOI:
- 10.2310/JIM.0b013e3181fb7ca7 ↗
- Languages:
- English
- ISSNs:
- 1081-5589
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.010000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17860.xml