Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only. Issue 9 (23rd January 2014)
- Record Type:
- Journal Article
- Title:
- Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only. Issue 9 (23rd January 2014)
- Main Title:
- Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only
- Authors:
- Greif, Martin
Lange, Philipp
Näbauer, Michael
Schwarz, Florian
Becker, Christoph
Schmitz, Christoph
Pohl, Tilmann
D'Anastasi, Melvin
Boekstegers, Peter
Massberg, Steffen
Kupatt, Christian - Abstract:
- Abstract : Objective: To assess the feasibility of transcatheter aortic valve implantation (TAVI; Medtronic CoreValve and Edwards SAPIEN XT) under local anaesthesia with only mild analgesic medication and fluoroscopic guidance. Methods: 461 patients underwent TAVI under local anaesthesia with lidocaine. The procedure was performed successfully in 459 of the cases. All patients were also treated with piritramide, metoclopramide hydrochloride and 62 mg dimenhydrinate. Monitoring consisted of a six-electrode, virtual 12-lead ECG, pulse oximetry, and invasive arterial pressure measurement. There was no continuous surveillance by an anaesthesiologist. Results: There was no need for conversion to general anaesthesia except in four patients who required cardiopulmonary resuscitation. Conscious sedation with intravenous administration of midazolam for agitation or inotropic medication for prolonged hypotension was necessary in only seven of the 461 patients. The combined safety end point according to the Valve Academic Research Consortium consensus document was reached in 12.6%. Conclusions: Our results show that TAVI performed under local anaesthesia with only mild analgesic medication and under fluoroscopic guidance is feasible, with good outcome comparable to published data.
- Is Part Of:
- Heart. Volume 100:Issue 9(2014)
- Journal:
- Heart
- Issue:
- Volume 100:Issue 9(2014)
- Issue Display:
- Volume 100, Issue 9 (2014)
- Year:
- 2014
- Volume:
- 100
- Issue:
- 9
- Issue Sort Value:
- 2014-0100-0009-0000
- Page Start:
- 691
- Page End:
- 695
- Publication Date:
- 2014-01-23
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2013-304918 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17858.xml