Efficacy of percutaneous closure of patent foramen ovale: comparison among three commonly used occluders. Issue 5 (4th February 2011)
- Record Type:
- Journal Article
- Title:
- Efficacy of percutaneous closure of patent foramen ovale: comparison among three commonly used occluders. Issue 5 (4th February 2011)
- Main Title:
- Efficacy of percutaneous closure of patent foramen ovale: comparison among three commonly used occluders
- Authors:
- Thaman, R
Faganello, G
Gimeno, J R
Szantho, G V
Nelson, M
Curtis, S
Martin, R P
Turner, M S - Abstract:
- Abstract : Background: Percutaneous closure of patent foramen ovale (PFO) is standard treatment for patients with paradoxical embolism but studies examining the efficacy of the various occluders are lacking. Objective: To evaluate short- and medium-term closure rates of three common occluders. Methods: One hundred and sixty-six adults (47±12 (18–81 years)) were evaluated with transthoracic bubble echocardiography before and after PFO closure. Only patients with large PFOs were included (>30 bubbles in the left heart after Valsalva). Results: Three occluders were used: Amplatzer (AGA Medical Corporation) (n=80, 48%), Gore Helex (n=48, 29%) and Premere TM (St Jude Medical) (n=38, 23%). One (0.6%) neurological event occurred during follow-up. At 6 months significant residual shunting after Valsalva was highest in the group that received the Helex (58.3%), and lower for Premere (39.5%) and Amplatzer (32.5%). At final follow-up residual shunting remained higher in patients with the Helex (33.3%) than in Premere (18.5%) and Amplatzer (11%). Amplatzer had a significantly lower residual shunt rate than Helex (p<0.05 at 6 months and final follow-up). The Premere had an intermediate residual shunt rate. Septal aneurysm also predicted residual shunting (RR=24.7, 95% CI: 8.2 to 74.4, p<0.0001). Conclusions: Percutaneous PFO closure is an efficacious progressive treatment but closure rates also depend on the presence of aneurysm and differ between occluders.
- Is Part Of:
- Heart. Volume 97:Issue 5(2011)
- Journal:
- Heart
- Issue:
- Volume 97:Issue 5(2011)
- Issue Display:
- Volume 97, Issue 5 (2011)
- Year:
- 2011
- Volume:
- 97
- Issue:
- 5
- Issue Sort Value:
- 2011-0097-0005-0000
- Page Start:
- 394
- Page End:
- 399
- Publication Date:
- 2011-02-04
- Subjects:
- Patent foramen ovale -- septal occluder -- stroke -- transient ischaemic attack (TIA) -- echocardiography-contrast -- device closure
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2010.203950 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17859.xml