Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program. Issue 9 (6th March 2013)
- Record Type:
- Journal Article
- Title:
- Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program. Issue 9 (6th March 2013)
- Main Title:
- Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program
- Authors:
- Farooq, Vasim
Vranckx, Pascal
Mauri, Laura
Cutlip, Donald E
Belardi, Jorge
Silber, Sigmund
Widimsky, Petr
Leon, Martin
Windecker, Stephan
Meredith, Ian
Negoita, Manuela
van Leeuwen, Frank
Neumann, Franz-Joseph
Yeung, Alan C
Garcia-Garcia, Hector M
Serruys, Patrick W - Abstract:
- Abstract : Background: Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes—including death and myocardial infarction (MI)—in clinical studies. Objectives: To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). Design: Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan–Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. Setting: Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrolment criteria were generally unrestrictive. Patients: 5130 patients. Main outcome measures: 2-year clinical outcomes and 13-month angiographic outcomes. Results: 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicatedAbstract : Background: Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes—including death and myocardial infarction (MI)—in clinical studies. Objectives: To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). Design: Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan–Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. Setting: Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrolment criteria were generally unrestrictive. Patients: 5130 patients. Main outcome measures: 2-year clinical outcomes and 13-month angiographic outcomes. Results: 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES. Conclusions: Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes—including repeat revascularisation—to non-overlapping DES. ClinicalTrials.gov Identifiers: NCT00248079; NCT00617084 ; NCT00726453 ; NCT00752128 ; NCT00927940 . … (more)
- Is Part Of:
- Heart. Volume 99:Issue 9(2013)
- Journal:
- Heart
- Issue:
- Volume 99:Issue 9(2013)
- Issue Display:
- Volume 99, Issue 9 (2013)
- Year:
- 2013
- Volume:
- 99
- Issue:
- 9
- Issue Sort Value:
- 2013-0099-0009-0000
- Page Start:
- 626
- Page End:
- 633
- Publication Date:
- 2013-03-06
- Subjects:
- INTERVENTIONAL CARDIOLOGY
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2012-303368 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17858.xml