Altering standard admission order sets to promote clinical laboratory stewardship: a cohort quality improvement study. Issue 10 (9th May 2019)
- Record Type:
- Journal Article
- Title:
- Altering standard admission order sets to promote clinical laboratory stewardship: a cohort quality improvement study. Issue 10 (9th May 2019)
- Main Title:
- Altering standard admission order sets to promote clinical laboratory stewardship: a cohort quality improvement study
- Authors:
- Leis, Benjamin
Frost, Andrew
Bryce, Rhonda
Lyon, Andrew W
Coverett, Kelly - Abstract:
- Abstract : Background: Careful design of preprinted order sets is needed to prevent medical overuse. Recent work suggests that removing a single checkbox from an order set changes physicians' clinical decision-making. Local problem: During a 2-month period, our coronary care unit (CCU) ordered almost eight times as many serum thyroid-stimulating hormone (TSH) tests as our neighbouring intensive care unit, many without a reasonable clinical basis. We postulated that we could reduce inappropriate testing and improve clinical laboratory stewardship by removing the TSH checkbox from the CCU admission order set. Methods: After we retrospectively evaluated CCU TSH ordering before intervention, the checkbox was removed from the CCU admission order set. Twelve weeks later, we commenced a prospective 2-month assessment of TSH testing and clinical sequelae of thyroid disease among all CCU admissions. If clinical indications were absent or testing had occurred within 6 weeks, TSH requests were labelled as 'inappropriate'. Results: Physician ordering and, specifically, inappropriate ordering decreased substantially after the intervention. In 2016 among physician-ordered TSH tests, 60.6% (66/109) were inappropriate; in 2017 this decreased to 20% (2/10, p=0.01). Overall, the net effect of checkbox removal saw the decrease in TSH testing without clinical indication outweigh an increase in missed testing where indications appear to exist. Conclusions: Provision of an optional checkbox for aAbstract : Background: Careful design of preprinted order sets is needed to prevent medical overuse. Recent work suggests that removing a single checkbox from an order set changes physicians' clinical decision-making. Local problem: During a 2-month period, our coronary care unit (CCU) ordered almost eight times as many serum thyroid-stimulating hormone (TSH) tests as our neighbouring intensive care unit, many without a reasonable clinical basis. We postulated that we could reduce inappropriate testing and improve clinical laboratory stewardship by removing the TSH checkbox from the CCU admission order set. Methods: After we retrospectively evaluated CCU TSH ordering before intervention, the checkbox was removed from the CCU admission order set. Twelve weeks later, we commenced a prospective 2-month assessment of TSH testing and clinical sequelae of thyroid disease among all CCU admissions. If clinical indications were absent or testing had occurred within 6 weeks, TSH requests were labelled as 'inappropriate'. Results: Physician ordering and, specifically, inappropriate ordering decreased substantially after the intervention. In 2016 among physician-ordered TSH tests, 60.6% (66/109) were inappropriate; in 2017 this decreased to 20% (2/10, p=0.01). Overall, the net effect of checkbox removal saw the decrease in TSH testing without clinical indication outweigh an increase in missed testing where indications appear to exist. Conclusions: Provision of an optional checkbox for a laboratory test in an admission order set can promote overuse of laboratory resources . Simple removal of a checkbox may dramatically change test ordering patterns and promote clinical laboratory stewardship. Given our reliance on order sets, particularly by trainees, changes to order sets must be cautious to assure guideline-directed care is maintained. … (more)
- Is Part Of:
- BMJ quality & safety. Volume 28:Issue 10(2019)
- Journal:
- BMJ quality & safety
- Issue:
- Volume 28:Issue 10(2019)
- Issue Display:
- Volume 28, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 10
- Issue Sort Value:
- 2019-0028-0010-0000
- Page Start:
- 846
- Page End:
- 852
- Publication Date:
- 2019-05-09
- Subjects:
- clinical decision-making -- medical overuse -- TSH -- intensive care units -- coronary care units
Medical care -- Quality control -- Periodicals
Health facilities -- Risk management -- Periodicals
Medical errors -- Prevention -- Periodicals
362.106805 - Journal URLs:
- http://www.bmj.com/archive ↗
http://qualitysafety.bmj.com/ ↗ - DOI:
- 10.1136/bmjqs-2018-008995 ↗
- Languages:
- English
- ISSNs:
- 2044-5415
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17804.xml