A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer. Issue 3 (14th December 2016)
- Record Type:
- Journal Article
- Title:
- A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer. Issue 3 (14th December 2016)
- Main Title:
- A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer
- Authors:
- Passamonti, Basilio
Malaspina, Morena
Fraser, Callum G
Tintori, Beatrice
Carlani, Angela
D'Angelo, Valentina
Galeazzi, Paola
Di Dato, Eugenio
Mariotti, Loretta
Bulletti, Simonetta
D'Amico, Maria Rosaria
Gustinucci, Daniela
Martinelli, Nadia
Spita, Nicoletta
Cesarini, Elena
Rubeca, Tiziana
Giaimo, Mariadonata
Segnan, Nereo
Senore, Carlo - Abstract:
- Abstract : Aim: To compare acceptability and diagnostic accuracy of a recently available faecal immunochemical test (FIT) system (HM-JACKarc) with the FIT routinely used in an established screening programme (OC-Sensor). Design: Randomised controlled trial (ISRCTN20086618 ) within a population-based colorectal cancer (CRC) screening programme. Subjects eligible for invitation in the Umbria Region (Italy) programme were randomised (ratio 1:1) to be screened using one of the FIT systems. Results: Screening uptake among the 48 888 invitees was the same for both systems among subjects invited in the first round and higher with OC-Sensor than with HM-JACKarc (relative risk (RR): 1.03; 95% CI 1.02 to 1.04) among those invited in subsequent rounds. Positivity rate (PR) was similar with OC-Sensor (6.5%) as with HM-JACKarc (6.2%) among subjects performing their first FIT screening and higher with OC-Sensor (5.6%, RR: 1.25, 95% CI 1.12 to 1.40) than with HM-JACKarc (4.4%) among those screened in previous rounds. Positive predictive value (PPV) (OC-Sensor: 25.9%, HM-JACKarc: 25.6%) and detection rate (DR) (OC-Sensor: 1.40%; HM-JACKarc: 1.42%) for advanced neoplasia (AN: CRC + advanced adenoma) were similar among subjects performing their first FIT screening. The differences in the AN PPV (OC-Sensor: 20.3%, HM-JACKarc: 22.6%) and DR (OC-Sensor: 0.96%, HM-JACKarc: 0.83%) among those screened in previous rounds were not statistically significant. The number needed to scope to detect oneAbstract : Aim: To compare acceptability and diagnostic accuracy of a recently available faecal immunochemical test (FIT) system (HM-JACKarc) with the FIT routinely used in an established screening programme (OC-Sensor). Design: Randomised controlled trial (ISRCTN20086618 ) within a population-based colorectal cancer (CRC) screening programme. Subjects eligible for invitation in the Umbria Region (Italy) programme were randomised (ratio 1:1) to be screened using one of the FIT systems. Results: Screening uptake among the 48 888 invitees was the same for both systems among subjects invited in the first round and higher with OC-Sensor than with HM-JACKarc (relative risk (RR): 1.03; 95% CI 1.02 to 1.04) among those invited in subsequent rounds. Positivity rate (PR) was similar with OC-Sensor (6.5%) as with HM-JACKarc (6.2%) among subjects performing their first FIT screening and higher with OC-Sensor (5.6%, RR: 1.25, 95% CI 1.12 to 1.40) than with HM-JACKarc (4.4%) among those screened in previous rounds. Positive predictive value (PPV) (OC-Sensor: 25.9%, HM-JACKarc: 25.6%) and detection rate (DR) (OC-Sensor: 1.40%; HM-JACKarc: 1.42%) for advanced neoplasia (AN: CRC + advanced adenoma) were similar among subjects performing their first FIT screening. The differences in the AN PPV (OC-Sensor: 20.3%, HM-JACKarc: 22.6%) and DR (OC-Sensor: 0.96%, HM-JACKarc: 0.83%) among those screened in previous rounds were not statistically significant. The number needed to scope to detect one AN was 3.9 (95% CI 5.8 to 2.9) and 3.9 (95% CI 5.5 to 2.9) at first and 4.9 (95% CI 5.8 to 4.2) and 4.4 (95% CI 5.3 to 3.7) at subsequent screening, with OC-Sensor and HM-JACKarc, respectively. Conclusions: Our results suggest that acceptability and diagnostic performance of HM-JACKarc and of OC-Sensor systems are similar in a screening setting. Trial registration number: ISRCTN20086618 ; Results. … (more)
- Is Part Of:
- Gut. Volume 67:Issue 3(2018)
- Journal:
- Gut
- Issue:
- Volume 67:Issue 3(2018)
- Issue Display:
- Volume 67, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 67
- Issue:
- 3
- Issue Sort Value:
- 2018-0067-0003-0000
- Page Start:
- 485
- Page End:
- 496
- Publication Date:
- 2016-12-14
- Subjects:
- CANCER PREVENTION -- SCREENING -- COLORECTAL CANCER SCREENING
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gutjnl-2016-312716 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17832.xml