The effect of different lower detection thresholds in microdosimetric spectra and their mean values. (August 2021)
- Record Type:
- Journal Article
- Title:
- The effect of different lower detection thresholds in microdosimetric spectra and their mean values. (August 2021)
- Main Title:
- The effect of different lower detection thresholds in microdosimetric spectra and their mean values
- Authors:
- Bianchi, Anna
Selva, Anna
Colautti, Paolo
Parisi, Alessio
Vanhavere, Filip
Reniers, Brigitte
Conte, Valeria - Abstract:
- Abstract: Research on the applications of microdosimetry to particle therapy is spreading worldwide with a rapid increase of publications in the last years. In order to be able to perform an intercomparison of data acquired with different detectors in different clinical centres it is important to analyse data with a standard procedure. Often microdosimetric spectra are presented with different lower detection thresholds, in relation with different detection sensitivity and noise levels. The purpose of this paper is to analyse the influence of the lower detection threshold on the dose-mean lineal energy values, which are used as an assessment of the average LET of the radiation field. Furthermore, the dose distribution of the lineal energy can be used in combination with biological weighting functions to estimate the biological RBE at different positions along the penetration depths of therapeutic proton or carbon ion beams. Microdosimetric spectra cut at different lower thresholds lead in principle to different RBE values. It was an additional purpose of this work to analyse and discuss this effect both for proton and carbon ion irradiations. Spectra in proton and carbon ion beams gathered with a miniaturized TEPC developed at the Legnaro National Laboratories of the Italian Institute for Nuclear Physics (LNL-INFN) have been used to perform this study. Linear extrapolation of the microdosimetric spectra to a common value of 0.01 keV/μm significantly reduces the deviations inAbstract: Research on the applications of microdosimetry to particle therapy is spreading worldwide with a rapid increase of publications in the last years. In order to be able to perform an intercomparison of data acquired with different detectors in different clinical centres it is important to analyse data with a standard procedure. Often microdosimetric spectra are presented with different lower detection thresholds, in relation with different detection sensitivity and noise levels. The purpose of this paper is to analyse the influence of the lower detection threshold on the dose-mean lineal energy values, which are used as an assessment of the average LET of the radiation field. Furthermore, the dose distribution of the lineal energy can be used in combination with biological weighting functions to estimate the biological RBE at different positions along the penetration depths of therapeutic proton or carbon ion beams. Microdosimetric spectra cut at different lower thresholds lead in principle to different RBE values. It was an additional purpose of this work to analyse and discuss this effect both for proton and carbon ion irradiations. Spectra in proton and carbon ion beams gathered with a miniaturized TEPC developed at the Legnaro National Laboratories of the Italian Institute for Nuclear Physics (LNL-INFN) have been used to perform this study. Linear extrapolation of the microdosimetric spectra to a common value of 0.01 keV/μm significantly reduces the deviations in the mean values due to different lower thresholds. It is advisable to perform this procedure to have uniformity in data analysis and facilitate the intercomparison of data. Highlights: The influence of data analysis on microdosimetric results in clinical beams. Definition of a standard microdosimetric procedure for clinical applications. How to linearly extrapolate microdosimetric spectra to allow data intercomparison. … (more)
- Is Part Of:
- Radiation measurements. Volume 146(2021)
- Journal:
- Radiation measurements
- Issue:
- Volume 146(2021)
- Issue Display:
- Volume 146, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 146
- Issue:
- 2021
- Issue Sort Value:
- 2021-0146-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Microdosimetry -- Mini-TEPC -- Particle therapy -- Linear extrapolation
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2021.106626 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17782.xml