Static balloon atrial septostomy in Japan in shortage of standard balloon septostomy catheter. Issue 3 (September 2021)
- Record Type:
- Journal Article
- Title:
- Static balloon atrial septostomy in Japan in shortage of standard balloon septostomy catheter. Issue 3 (September 2021)
- Main Title:
- Static balloon atrial septostomy in Japan in shortage of standard balloon septostomy catheter
- Authors:
- Baba, Kenji
Suda, Kenji
Takamuro, Motoki
Takahashi, Shin
Sugiyama, Hisashi
Fujimoto, Kazuto
Kitano, Masataka
Fujii, Takanari
Kise, Hiroaki
Ohtsuki, Sinichi
Tomita, Hideshi - Abstract:
- Highlights: A questionnaire survey of balloon atrial septostomy (BAS) in Japan was conducted. In Japan, the BAS catheter supply has been discontinued due to its recall. Static BAS is widely done despite being off-label in Japan and is effective and safe. Static BAS cases increased by over 90% due to a shortage of BAS catheter. An adequate supply of the BAS catheter, such as Z-5, is indispensable in Japan. Abstract: Background: The supply of Rashkind balloon atrial septostomy (BAS) catheters (Medtronic, Minneapolis, MN, USA) has suddenly been discontinued in the world due to its recall. Consequently, Japan fell into a critical shortage of standard BAS catheters. Although the use of static BAS is off-label in Japan, its importance is increasing in such a situation. A nationwide survey of static BAS is needed in such a critical period. Methods: A questionnaire survey was conducted among centers in Japan regarding BAS performed between October 1, 2020, and December 15, 2020, while the supply of Rashkind BAS catheter was discontinued. Results: We received answers from 70 of the 90 centers, for a response rate of 78%. In this survey, 25 patients who underwent static BAS were enrolled, and a total of 47 BAS procedures were performed. Median age and weight at static BAS were 10 days of life and 3001 g, respectively. The most common diagnosis was transposition of the great arteries without pulmonary stenosis and hypoplastic left heart syndrome and its variants, with 8 cases each. TheHighlights: A questionnaire survey of balloon atrial septostomy (BAS) in Japan was conducted. In Japan, the BAS catheter supply has been discontinued due to its recall. Static BAS is widely done despite being off-label in Japan and is effective and safe. Static BAS cases increased by over 90% due to a shortage of BAS catheter. An adequate supply of the BAS catheter, such as Z-5, is indispensable in Japan. Abstract: Background: The supply of Rashkind balloon atrial septostomy (BAS) catheters (Medtronic, Minneapolis, MN, USA) has suddenly been discontinued in the world due to its recall. Consequently, Japan fell into a critical shortage of standard BAS catheters. Although the use of static BAS is off-label in Japan, its importance is increasing in such a situation. A nationwide survey of static BAS is needed in such a critical period. Methods: A questionnaire survey was conducted among centers in Japan regarding BAS performed between October 1, 2020, and December 15, 2020, while the supply of Rashkind BAS catheter was discontinued. Results: We received answers from 70 of the 90 centers, for a response rate of 78%. In this survey, 25 patients who underwent static BAS were enrolled, and a total of 47 BAS procedures were performed. Median age and weight at static BAS were 10 days of life and 3001 g, respectively. The most common diagnosis was transposition of the great arteries without pulmonary stenosis and hypoplastic left heart syndrome and its variants, with 8 cases each. The most frequently used balloon diameter was 10 mm (13 balloons), followed by 12 mm (10 balloons), and 3 cases required double-balloon techniques. The 3-point scale of the efficacy of static BAS rated by physicians were 10 excellent, 15 good, and 0 poor, respectively. Complications included cardiac tamponade during the procedure in 1 patient and the need for Rashkind BAS later in 2 patients. Comparing the share of static BAS in all transcatheter atrial septostomy, its share in the current survey (28/53) is significantly higher compared to the annual registry data in 2018 (86/304) ( p < 0.01). Conclusions: This survey shows that static BAS is widely performed in Japan and is effective and safe. Static BAS cases have increased significantly due to a shortage of standard BAS catheters. … (more)
- Is Part Of:
- Journal of cardiology. Volume 78:Issue 3(2021)
- Journal:
- Journal of cardiology
- Issue:
- Volume 78:Issue 3(2021)
- Issue Display:
- Volume 78, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 78
- Issue:
- 3
- Issue Sort Value:
- 2021-0078-0003-0000
- Page Start:
- 219
- Page End:
- 223
- Publication Date:
- 2021-09
- Subjects:
- Catheter intervention -- Congenital heart disease -- Balloon atrial septostomy -- Static balloon atrial septostomy
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/09145087 ↗
http://www.sciencedirect.com/science/journal/09145087 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jjcc.2021.04.008 ↗
- Languages:
- English
- ISSNs:
- 0914-5087
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.864200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17793.xml