201 IN VIVO WEAR OF LARGE FEMORAL HEADS ON HIGHLY CROSS-LINKED POLYETHYLENE. (1st January 2006)
- Record Type:
- Journal Article
- Title:
- 201 IN VIVO WEAR OF LARGE FEMORAL HEADS ON HIGHLY CROSS-LINKED POLYETHYLENE. (1st January 2006)
- Main Title:
- 201 IN VIVO WEAR OF LARGE FEMORAL HEADS ON HIGHLY CROSS-LINKED POLYETHYLENE.
- Authors:
- Aspey, B.
Beaulé, P. E.
Martell, J.
Ebramzadeh, E.
Amstutz, H. C. - Abstract:
- Abstract : Introduction: Highly cross-linked polyethylene has been shown in hip simulator studies to reduce wear by 80% to 90% when compared to conventional polyethylene. The goal of this study was to evaluate the in vivo wear of a highly cross-linked polyethylene against femoral head sizes larger than 32 mm. Materials and Methods: Volumetric and linear wear rates were measured in two groups of patients with femoral heads larger than 32 mm. Thirteen hips received a highly cross-linked polyethylene liner and 13 hips received a conventional polyethylene liner. Volumetric and linear wear rates were measured on radiographs with use of a validated computer-assisted technique ( Hip Analysis Suite, version 7.0). Results: The highly cross-linked polyethylene had a mean volumetric and linear wear rate of 117.5 ± 103.8 mm 3 and 0.15 ± 0.10 mm per year, respectively. The conventional polyethylene had a mean volumetric and linear wear rate of 375.7 ± 153.8 mm 3 and 0.36 ± 0.16 mm per year, respectively. The volumetric and linear wear rates in the group with the highly cross-linked polyethylene liner were 69% ( p < .0009) and 58% (p < .0007) lower, respectively. There was no significant difference in gender, age, weight, femoral head size, abduction angle, or UCLA activity score between the two groups. Discussion: While hip simulator studies predict a 80% to 90% reduction in wear, the difference between the in vitro and in vivo results could be a result of bedding-in-effect and creep.Abstract : Introduction: Highly cross-linked polyethylene has been shown in hip simulator studies to reduce wear by 80% to 90% when compared to conventional polyethylene. The goal of this study was to evaluate the in vivo wear of a highly cross-linked polyethylene against femoral head sizes larger than 32 mm. Materials and Methods: Volumetric and linear wear rates were measured in two groups of patients with femoral heads larger than 32 mm. Thirteen hips received a highly cross-linked polyethylene liner and 13 hips received a conventional polyethylene liner. Volumetric and linear wear rates were measured on radiographs with use of a validated computer-assisted technique ( Hip Analysis Suite, version 7.0). Results: The highly cross-linked polyethylene had a mean volumetric and linear wear rate of 117.5 ± 103.8 mm 3 and 0.15 ± 0.10 mm per year, respectively. The conventional polyethylene had a mean volumetric and linear wear rate of 375.7 ± 153.8 mm 3 and 0.36 ± 0.16 mm per year, respectively. The volumetric and linear wear rates in the group with the highly cross-linked polyethylene liner were 69% ( p < .0009) and 58% (p < .0007) lower, respectively. There was no significant difference in gender, age, weight, femoral head size, abduction angle, or UCLA activity score between the two groups. Discussion: While hip simulator studies predict a 80% to 90% reduction in wear, the difference between the in vitro and in vivo results could be a result of bedding-in-effect and creep. These are promising initial results that will improve the long-term survival of surface and total hip arthroplasties. … (more)
- Is Part Of:
- Journal of investigative medicine. Volume 54:Number 1(2006)
- Journal:
- Journal of investigative medicine
- Issue:
- Volume 54:Number 1(2006)
- Issue Display:
- Volume 54, Issue 1 (2006)
- Year:
- 2006
- Volume:
- 54
- Issue:
- 1
- Issue Sort Value:
- 2006-0054-0001-0000
- Page Start:
- S114
- Page End:
- S114
- Publication Date:
- 2006-01-01
- Subjects:
- Clinical medicine -- Periodicals
Medicine -- Research -- Periodicals
Medicine
Research -- United States
Clinical medicine
Medicine -- Research
Periodicals
616.075 - Journal URLs:
- http://journals.lww.com/jinvestigativemed/pages/default.aspx ↗
http://jim.bmj.com/ ↗
https://journals.sagepub.com/home/IMJ ↗
http://journals.lww.com ↗ - DOI:
- 10.2310/6650.2005.X0004.200 ↗
- Languages:
- English
- ISSNs:
- 1081-5589
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.010000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17781.xml