Quick-multiplex-consensus (QMC)-PCR followed by high-resolution melting: a simple and robust method for mutation detection in formalin-fixed paraffin-embedded tissue. Issue 2 (12th February 2010)
- Record Type:
- Journal Article
- Title:
- Quick-multiplex-consensus (QMC)-PCR followed by high-resolution melting: a simple and robust method for mutation detection in formalin-fixed paraffin-embedded tissue. Issue 2 (12th February 2010)
- Main Title:
- Quick-multiplex-consensus (QMC)-PCR followed by high-resolution melting: a simple and robust method for mutation detection in formalin-fixed paraffin-embedded tissue
- Authors:
- Fadhil, Wakkas
Ibrahem, Salih
Seth, Rashmi
Ilyas, Mohammad - Abstract:
- Abstract : Background: Mutation detection in tumours will become increasingly important in pathological diagnosis as 'predictive' mutations are identified. A cheap and reliable test that works on formalin-fixed paraffin-embedded (FFPE) tissue is required. Methods: The quick-multiplex-consensus (QMC)-PCR protocol was developed to be used with high-resolution melting (HRM) analysis. The assay was compared with Sanger sequencing. Robustness of the assay was tested in DNA from FFPE tissue. Results: QMC-PCR with HRM could detect a minimum of 2.5% of mutant alleles (compared with 20% detectable for Sanger sequencing). Ten mutation hotspots in KRAS, BRAF, PIK3CA and CDC4 were screened in 29 cell lines with 100% sensitivity and specificity. Forty-three FFPE colorectal tumours were sequenced for hotspots in KRAS and PIK3CA and then screened by QMC-PCR. There was 100% sensitivity, although, of 21 mutations detected by QMC-PCR, 16 were confirmed by sequencing (71% specificity, positive predictive value 76%). All 43 samples were then screened for mutations in all 10 hotspots. Of 430 tests, 43 (10%) showed aberrant melting and 36 were confirmed mutant (positive predictive value 84%). As our technique is more sensitive than direct sequencing, the remaining seven tests are probably sequencing false-negatives. Precision tests showed that there was little intra-assay and interassay variation. Conclusions: QMC-PCR with HRM is a simple, robust and inexpensive technique which had greaterAbstract : Background: Mutation detection in tumours will become increasingly important in pathological diagnosis as 'predictive' mutations are identified. A cheap and reliable test that works on formalin-fixed paraffin-embedded (FFPE) tissue is required. Methods: The quick-multiplex-consensus (QMC)-PCR protocol was developed to be used with high-resolution melting (HRM) analysis. The assay was compared with Sanger sequencing. Robustness of the assay was tested in DNA from FFPE tissue. Results: QMC-PCR with HRM could detect a minimum of 2.5% of mutant alleles (compared with 20% detectable for Sanger sequencing). Ten mutation hotspots in KRAS, BRAF, PIK3CA and CDC4 were screened in 29 cell lines with 100% sensitivity and specificity. Forty-three FFPE colorectal tumours were sequenced for hotspots in KRAS and PIK3CA and then screened by QMC-PCR. There was 100% sensitivity, although, of 21 mutations detected by QMC-PCR, 16 were confirmed by sequencing (71% specificity, positive predictive value 76%). All 43 samples were then screened for mutations in all 10 hotspots. Of 430 tests, 43 (10%) showed aberrant melting and 36 were confirmed mutant (positive predictive value 84%). As our technique is more sensitive than direct sequencing, the remaining seven tests are probably sequencing false-negatives. Precision tests showed that there was little intra-assay and interassay variation. Conclusions: QMC-PCR with HRM is a simple, robust and inexpensive technique which had greater sensitivity than Sanger sequencing. It allows multiple mutation hotspots to be rapidly screened and is thus highly suited to mutation detection in DNA derived from FFPE tissues. … (more)
- Is Part Of:
- Journal of clinical pathology. Volume 63:Issue 2(2010)
- Journal:
- Journal of clinical pathology
- Issue:
- Volume 63:Issue 2(2010)
- Issue Display:
- Volume 63, Issue 2 (2010)
- Year:
- 2010
- Volume:
- 63
- Issue:
- 2
- Issue Sort Value:
- 2010-0063-0002-0000
- Page Start:
- 134
- Page End:
- 140
- Publication Date:
- 2010-02-12
- Subjects:
- PCR -- HRM -- mutation detection -- formalin-fixed paraffin-embedded -- cancer genetics -- DNA -- molecular pathology
Pathology -- Periodicals
Pathology, Molecular -- Periodicals
616.0705 - Journal URLs:
- http://jcp.bmjjournals.com ↗
http://jcp.bmjjournals.com/content/by/year ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=162&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/jcp.2009.070508 ↗
- Languages:
- English
- ISSNs:
- 0021-9746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17794.xml