Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study. Issue 5 (30th May 2014)
- Record Type:
- Journal Article
- Title:
- Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study. Issue 5 (30th May 2014)
- Main Title:
- Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study
- Authors:
- Tekath, Marielle
Dutheil, Frédéric
Bellini, Romain
Roche, Antoine
Pereira, Bruno
Naughton, Geraldine
Chamoux, Alain
Michel, Jean-Luc - Abstract:
- Abstract : Objectives: Radiation delivered during CT is a major concern, especially for individuals undergoing repeated screening. We aimed to compare a new ultra-low-dose algorithm called Veo with the gold standard filtered back projection (FBP) for detecting pulmonary asbestos-related conditions. Setting: University Hospital CHU G. Montpied, Clermont-Ferrand, France Participants: Asbestos-exposed workers were recruited following referral to screening for asbestos-related conditions. Two acquisitions were performed on a 64-slice CT: the gold standard FBP followed by Veo reconstruction. Outcome measures: Two radiologists independently assessed asbestos-related abnormalities, pulmonary nodules, radiation doses and image quality (noise). Results: We included 27 asbestos-exposed workers (63.3±6.5 years with 11.9±9.7 years of asbestos exposure). We observed 297 pleural plaques in 20 participants (74%). All patients (100%) had pulmonary nodules, totalling 167 nodules. Detection rates did not differ for pleural plaques ( Veo 87% vs FBP 97%, NS), pleural thickening (100% for both) and pulmonary nodules (80% for both). Interstitial abnormalities were depicted less frequently with Veo than FBP. False negative and false positive did not exceed 2.7%. Compared with FBP, Veo decreased the radiation dose up to 87% ( Veo 0.23±0.07 vs FBP 1.83±0.88 mSv, p<0.001). The objective image noise also decreased with Veo as much as 23% and signal-to-noise ratio increased up to 33%. Conclusions: AAbstract : Objectives: Radiation delivered during CT is a major concern, especially for individuals undergoing repeated screening. We aimed to compare a new ultra-low-dose algorithm called Veo with the gold standard filtered back projection (FBP) for detecting pulmonary asbestos-related conditions. Setting: University Hospital CHU G. Montpied, Clermont-Ferrand, France Participants: Asbestos-exposed workers were recruited following referral to screening for asbestos-related conditions. Two acquisitions were performed on a 64-slice CT: the gold standard FBP followed by Veo reconstruction. Outcome measures: Two radiologists independently assessed asbestos-related abnormalities, pulmonary nodules, radiation doses and image quality (noise). Results: We included 27 asbestos-exposed workers (63.3±6.5 years with 11.9±9.7 years of asbestos exposure). We observed 297 pleural plaques in 20 participants (74%). All patients (100%) had pulmonary nodules, totalling 167 nodules. Detection rates did not differ for pleural plaques ( Veo 87% vs FBP 97%, NS), pleural thickening (100% for both) and pulmonary nodules (80% for both). Interstitial abnormalities were depicted less frequently with Veo than FBP. False negative and false positive did not exceed 2.7%. Compared with FBP, Veo decreased the radiation dose up to 87% ( Veo 0.23±0.07 vs FBP 1.83±0.88 mSv, p<0.001). The objective image noise also decreased with Veo as much as 23% and signal-to-noise ratio increased up to 33%. Conclusions: A low-dose CT with Veo reconstruction substantially reduced radiation. Veo compared favourably with FBP in detecting pleural plaques, pleural thickening and pulmonary nodules. These results should be confirmed on a larger sample size before the use of Veo in clinical routine practice in asbestos-related conditions, especially regarding the low prevalence of interstitial abnormalities in this study. Trial registration number: NCT01955018. … (more)
- Is Part Of:
- BMJ open. Volume 4:Issue 5(2014)
- Journal:
- BMJ open
- Issue:
- Volume 4:Issue 5(2014)
- Issue Display:
- Volume 4, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 4
- Issue:
- 5
- Issue Sort Value:
- 2014-0004-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-05-30
- Subjects:
- OCCUPATIONAL & INDUSTRIAL MEDICINE -- PUBLIC HEALTH
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2014-004980 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17775.xml