Evaluation of fitting models for prostate tissue characterization using extended‐range b‐factor diffusion‐weighted imaging. Issue 4 (17th July 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of fitting models for prostate tissue characterization using extended‐range b‐factor diffusion‐weighted imaging. Issue 4 (17th July 2017)
- Main Title:
- Evaluation of fitting models for prostate tissue characterization using extended‐range b‐factor diffusion‐weighted imaging
- Authors:
- Langkilde, Fredrik
Kobus, Thiele
Fedorov, Andriy
Dunne, Ruth
Tempany, Clare
Mulkern, Robert V.
Maier, Stephan E. - Abstract:
- Abstract : Purpose: To compare the fitting and tissue discrimination performance of biexponential, kurtosis, stretched exponential, and gamma distribution models for high b‐factor diffusion‐weighted images in prostate cancer. Methods: Diffusion‐weighted images with 15 b‐factors ranging from b = 0 to 3500 s/mm 2 were obtained in 62 prostate cancer patients. Pixel‐wise signal decay fits for each model were evaluated with the Akaike Information Criterion (AIC). Parameter values for each model were determined within normal prostate and the index lesion. Their potential to differentiate normal from cancerous tissue was investigated through receiver operating characteristic analysis and comparison with Gleason score. Results: The biexponential slow diffusion fraction fslow, the apparent kurtosis diffusion coefficient ADCK, and the excess kurtosis factor K differ significantly among normal peripheral zone (PZ), normal transition zone (TZ), tumor PZ, and tumor TZ. Biexponential and gamma distribution models result in the lowest AIC, indicating a superior fit. Maximum areas under the curve (AUCs) of all models ranged from 0.93 to 0.96 for the PZ and from 0.95 to 0.97 for the TZ. Similar AUCs also result from the apparent diffusion coefficient (ADC) of a monoexponential fit to a b‐factor sub‐range up to 1250 s/mm 2 . For kurtosis and stretched exponential models, single parameters yield the highest AUCs, whereas for the biexponential and gamma distribution models, linear combinationsAbstract : Purpose: To compare the fitting and tissue discrimination performance of biexponential, kurtosis, stretched exponential, and gamma distribution models for high b‐factor diffusion‐weighted images in prostate cancer. Methods: Diffusion‐weighted images with 15 b‐factors ranging from b = 0 to 3500 s/mm 2 were obtained in 62 prostate cancer patients. Pixel‐wise signal decay fits for each model were evaluated with the Akaike Information Criterion (AIC). Parameter values for each model were determined within normal prostate and the index lesion. Their potential to differentiate normal from cancerous tissue was investigated through receiver operating characteristic analysis and comparison with Gleason score. Results: The biexponential slow diffusion fraction fslow, the apparent kurtosis diffusion coefficient ADCK, and the excess kurtosis factor K differ significantly among normal peripheral zone (PZ), normal transition zone (TZ), tumor PZ, and tumor TZ. Biexponential and gamma distribution models result in the lowest AIC, indicating a superior fit. Maximum areas under the curve (AUCs) of all models ranged from 0.93 to 0.96 for the PZ and from 0.95 to 0.97 for the TZ. Similar AUCs also result from the apparent diffusion coefficient (ADC) of a monoexponential fit to a b‐factor sub‐range up to 1250 s/mm 2 . For kurtosis and stretched exponential models, single parameters yield the highest AUCs, whereas for the biexponential and gamma distribution models, linear combinations of parameters produce the highest AUCs. Parameters with high AUC show a trend in differentiating low from high Gleason score, whereas parameters with low AUC show no such ability. Conclusion: All models, including a monoexponential fit to a lower‐b sub‐range, achieve similar AUCs for discrimination of normal and cancer tissue. The biexponential model, which is favored statistically, also appears to provide insight into disease‐related microstructural changes. Magn Reson Med 79:2346–2358, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 4(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 4(2018)
- Issue Display:
- Volume 79, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 4
- Issue Sort Value:
- 2018-0079-0004-0000
- Page Start:
- 2346
- Page End:
- 2358
- Publication Date:
- 2017-07-17
- Subjects:
- prostate cancer -- diffusion weighted imaging -- biexponential model -- kurtosis model -- stretched exponential model -- gamma distribution model
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26831 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17751.xml