SAT0395 Sonoelastography detects salivary gland dysfunction in patients with primary sjögren's syndrome. (23rd January 2014)
- Record Type:
- Journal Article
- Title:
- SAT0395 Sonoelastography detects salivary gland dysfunction in patients with primary sjögren's syndrome. (23rd January 2014)
- Main Title:
- SAT0395 Sonoelastography detects salivary gland dysfunction in patients with primary sjögren's syndrome
- Authors:
- Dejaco, C.
DeZordo, T.
Heber, D.
Lipp, R.
Lutfi, A.
Magyar, M.
Zauner, D.
Graninger, W.B.
Hermann, J. - Abstract:
- Abstract : Background: Sialoscintigraphy (Szinti) is used to investigate salivary gland function in patients with primary Sjögren's syndrome (pSS). Real-time sonoelastography (SElasto) indicates tissue rigidity of salivary glands and correlates with an impaired saliva production. Objectives: To investigate the value of SElasto and B-mode sonography to identify pSS patients with dysfunctional salivary glands. Methods: Prospective study on 37 pSS patients fulfilling the American-European consensus group criteria [mean age 59 years; 92% female; median disease duration 3.1 years]. Szinti was conducted according to a routine protocol and semiquantitative scoring was performed (1): each gland was graded into 3= severe dysfunction, 2= moderate dysfunction, 1= mild dysfunction or 0= normal function. B-mode sonography and SElasto of parotid and submandibular glands was performed using a GE Logiq E9 ultrasound device. Parenchymal homogenicity, echogenicity, hypoechogenic areals, hyperechoic reflections and clearness of glandular borders were also semiquantitatively scored (total score 0-48) (2). SElasto was used to examine the elasticity of glandular parenchyma and a semiquantitative rating was performed with 0=no, 1=up to 25%, 2=up to 50%, 3=up to 75% and 4=more than 75% hardened areas within the salivary gland (total score 0-16). Interobserver variability of sonography and Szinti were tested in 30% of pSS patients. Results: The mean Szinti score of pSS patients was 6.0 (±4.3). LossAbstract : Background: Sialoscintigraphy (Szinti) is used to investigate salivary gland function in patients with primary Sjögren's syndrome (pSS). Real-time sonoelastography (SElasto) indicates tissue rigidity of salivary glands and correlates with an impaired saliva production. Objectives: To investigate the value of SElasto and B-mode sonography to identify pSS patients with dysfunctional salivary glands. Methods: Prospective study on 37 pSS patients fulfilling the American-European consensus group criteria [mean age 59 years; 92% female; median disease duration 3.1 years]. Szinti was conducted according to a routine protocol and semiquantitative scoring was performed (1): each gland was graded into 3= severe dysfunction, 2= moderate dysfunction, 1= mild dysfunction or 0= normal function. B-mode sonography and SElasto of parotid and submandibular glands was performed using a GE Logiq E9 ultrasound device. Parenchymal homogenicity, echogenicity, hypoechogenic areals, hyperechoic reflections and clearness of glandular borders were also semiquantitatively scored (total score 0-48) (2). SElasto was used to examine the elasticity of glandular parenchyma and a semiquantitative rating was performed with 0=no, 1=up to 25%, 2=up to 50%, 3=up to 75% and 4=more than 75% hardened areas within the salivary gland (total score 0-16). Interobserver variability of sonography and Szinti were tested in 30% of pSS patients. Results: The mean Szinti score of pSS patients was 6.0 (±4.3). Loss function of 1, 2 or 4 salivary glands was present in 5.3%, 17.5% and 19.3% of patients, respectively. B-mode (corrcoeff 0.65, p<0.001) as well as SElasto scores (corrcoeff 0.39, p=0.02) correlated with the Szinti score. Patients with at least one dysfunctional salivary gland had higher B-mode [median 27.5 (range 10.0-44.0) vs. 12.0 (2.0-6.9) p<0.001] and SElasto scores [median 7.0 (range 3.0-12.0) vs. 6.0 (2.0-7.0) p=0.032] than patients with normal salivary gland function. In ROC curve analysis we found an area under the curve (AUC) of 0.91 (95%CI 0.8-1.0, p<0.001) and 0.73 (0.56-0.89, p=0.03) for B-mode sonography and SElasto, respectively, to detect patients with salivary gland dysfunction. A good reproducibility of B-mode and SElasto results was found as indicated by an ICC of 0.926 (95%CI 0.565-0.983) and 0.934 (0.787-0.981), respectively. Reproducibility of Szinti results was also good (kappa 0.871). Conclusions: Structural changes and increased rigidity of major salivary glands as demonstrated by B-mode sonography and SElasto, respectively correlates closely withsalivary gland dysfunction in patients with pSS. References: Shizukuishi K, Nagaoka S, Kinno Y, Saito M, Takahashi N, Kawamoto M et al. Scoring analysis of salivary gland scintigraphy in patients with Sjögren's syndrome. Ann Nucl Med 2003;17:627-31. Shizukuishi K, Nagaoka S, Kinno Y, Saito M, Takahashi N, Kawamoto M et al. Ultrasonographic changes of major salivary glands in primary Sjogren's syndrome. Diagnostic value of a novel scoring system. Rheumatology 2005;44:768-72 Disclosure of Interest: None Declared … (more)
- Is Part Of:
- Annals of the rheumatic diseases. Volume 71(2012)Supplement 3
- Journal:
- Annals of the rheumatic diseases
- Issue:
- Volume 71(2012)Supplement 3
- Issue Display:
- Volume 71, Issue 3 (2012)
- Year:
- 2012
- Volume:
- 71
- Issue:
- 3
- Issue Sort Value:
- 2012-0071-0003-0000
- Page Start:
- 606
- Page End:
- 606
- Publication Date:
- 2014-01-23
- Subjects:
- Rheumatism -- Periodicals
616.723005 - Journal URLs:
- http://ard.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=149&action=archive ↗
http://www.bmj.com/archive ↗
http://gateway.ovid.com/server3/ovidweb.cgi?T=JS&MODE=ovid&D=ovft&PAGE=titles&SEARCH=annals+of+the+rheumatic+diseases.tj&NEWS=N ↗ - DOI:
- 10.1136/annrheumdis-2012-eular.3341 ↗
- Languages:
- English
- ISSNs:
- 0003-4967
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17754.xml