Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography. Issue 8 (27th February 2007)
- Record Type:
- Journal Article
- Title:
- Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography. Issue 8 (27th February 2007)
- Main Title:
- Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography
- Authors:
- Lavanya, Raghavan
Teo, Livia
Friedman, David S
Aung, Han T
Baskaran, Mani
Gao, Hong
Alfred, Tamuno
Seah, Steve K
Kashiwagi, Kenji
Foster, Paul J
Aung, Tin - Abstract:
- Abstract : Aim: To compare anterior chamber depth measurements by three non-contact devices—the IOLMaster, scanning peripheral anterior chamber depth analyser (SPAC), and Visante anterior segment optical coherence tomography (AS-OCT) Methods: Prospective, cross sectional study of 497 phakic subjects over 50 years of age attending a community clinic in Singapore. Anterior chamber depth of the right eye was measured using all three techniques by the same investigator. Depth measurements were made from the corneal epithelium to the anterior lens surface. The values obtained were compared using Bland–Altman analysis. Results: 232 men and 265 women were examined (mean (SD) age, 63.4 (7.9) years). Mean anterior chamber depth was 3.08 (0.36) mm with IOLMaster, 3.10 (0.44) mm with SPAC, and 3.14 (0.34) mm with AS-OCT. A significant difference was present between the anterior chamber depth measurements recorded by the three devices (p<0.0001). Mean differences between the measurements were: AS-OCT v IOLMaster, 0.062 (0.007) mm (95% limits of agreement, −0.37 to 0.25 mm) (p<0.0001); AS-OCT v SPAC, 0.035 (0.011) mm (−0.44 to 0.51 mm) (p = 0.0001); SPAC v IOLMaster, 0.027 (0.012) mm (−0.57 to 0.50 mm) (p = 0.027). Conclusions: AS-OCT gave systematically deeper anterior chamber measurements than SPAC and IOL-Master. However, as the differences found were small they are unlikely to be clinically important.
- Is Part Of:
- British journal of ophthalmology. Volume 91:Issue 8(2007)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 91:Issue 8(2007)
- Issue Display:
- Volume 91, Issue 8 (2007)
- Year:
- 2007
- Volume:
- 91
- Issue:
- 8
- Issue Sort Value:
- 2007-0091-0008-0000
- Page Start:
- 1023
- Page End:
- 1026
- Publication Date:
- 2007-02-27
- Subjects:
- AS-OCT, anterior segment optical coherence tomography -- IOL, intraocular lens -- PCI, partial coherence interferometry -- SPAC, scanning peripheral anterior chamber depth analyser
anterior chamber depth -- biometry -- anterior segment -- angle closure -- optical coherence tomography
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjo.2006.113761 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17735.xml