PLASMODIUM FALCIPARUM INFECTION IN FEBRILE CONGOLESE CHILDREN: PREVALENCE OF CLINICAL MALARIA TEN YEARS AFTER INTRODUCTION OF ARTEMISININ-COMBINATION THERAPIES. (12th February 2017)
- Record Type:
- Journal Article
- Title:
- PLASMODIUM FALCIPARUM INFECTION IN FEBRILE CONGOLESE CHILDREN: PREVALENCE OF CLINICAL MALARIA TEN YEARS AFTER INTRODUCTION OF ARTEMISININ-COMBINATION THERAPIES. (12th February 2017)
- Main Title:
- PLASMODIUM FALCIPARUM INFECTION IN FEBRILE CONGOLESE CHILDREN: PREVALENCE OF CLINICAL MALARIA TEN YEARS AFTER INTRODUCTION OF ARTEMISININ-COMBINATION THERAPIES
- Authors:
- Etoka-Beka, Mandingha Kosso
Ntoumi, Francine
Kombo, Michael
Deibert, Julia
Poulain, Pierre
Vouvoungui, Christevy
Kobawila, Simon
Koukouikila-Koussounda, Félix - Abstract:
- Abstract : Background: The detailed assessment of the QT and corrected QT interval prolongation is recommended when testing new drugs. Generally the electrocardiograph automatically displays reliable values of the QT interval and corrected QT but morphological variations of the T wave may cause reading errors; hence the use of manual measurement as an alternative method. Our objective was to evaluate the correlation between the automatic and manual measurement of QT values. Methods: In Kolle from March 2012 to December 2015, an open randomised, phase III-b/IV study comparing dihydroartemisinine-piperaquine and pyronaridine-artesunate artemether-lumefantrine was conducted. An electrocardiograph cartridge with 12 electrodes coupled to a computer with the Tele Touch software was used for the electrocardiogram on Day 0 before the study drugs administration and on Day 2, two to four hours after the administration of the last dose of the antimalarial. The manual measurement of QT and QTc was made using the Bazett method [QTcB_m=(Number leaded×0.04×QTcF) / QTcB]. For prolonged QTc cases on Day 2, another measurement was done during the next scheduled visit (day 7, 14, 21, 28, 35 and 42) until the QTc normalised. Results: A total of 764 ECG were recorded with 398 participants. Different automatic and manual values of QT and QTc are scattered around different medium. Comparisons of different values of QT: p=0.1245 and QTc: p< 0.001 showed statistically significant differences and theAbstract : Background: The detailed assessment of the QT and corrected QT interval prolongation is recommended when testing new drugs. Generally the electrocardiograph automatically displays reliable values of the QT interval and corrected QT but morphological variations of the T wave may cause reading errors; hence the use of manual measurement as an alternative method. Our objective was to evaluate the correlation between the automatic and manual measurement of QT values. Methods: In Kolle from March 2012 to December 2015, an open randomised, phase III-b/IV study comparing dihydroartemisinine-piperaquine and pyronaridine-artesunate artemether-lumefantrine was conducted. An electrocardiograph cartridge with 12 electrodes coupled to a computer with the Tele Touch software was used for the electrocardiogram on Day 0 before the study drugs administration and on Day 2, two to four hours after the administration of the last dose of the antimalarial. The manual measurement of QT and QTc was made using the Bazett method [QTcB_m=(Number leaded×0.04×QTcF) / QTcB]. For prolonged QTc cases on Day 2, another measurement was done during the next scheduled visit (day 7, 14, 21, 28, 35 and 42) until the QTc normalised. Results: A total of 764 ECG were recorded with 398 participants. Different automatic and manual values of QT and QTc are scattered around different medium. Comparisons of different values of QT: p=0.1245 and QTc: p< 0.001 showed statistically significant differences and the concordance between automatic and manual tests was (QT: Rho_c=0.77 and QTc: Rho_c=0.46). Conclusions: Our results indicate no perfect match between automatic and manual methods for QT and QTc. Manual reading remains important to correct any machine errors during clinical studies. … (more)
- Is Part Of:
- BMJ global health. Volume 2(2017)Supplement 2
- Journal:
- BMJ global health
- Issue:
- Volume 2(2017)Supplement 2
- Issue Display:
- Volume 2, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 2
- Issue:
- 2
- Issue Sort Value:
- 2017-0002-0002-0000
- Page Start:
- A27
- Page End:
- A27
- Publication Date:
- 2017-02-12
- Subjects:
- World health -- Periodicals
362.105 - Journal URLs:
- http://www.bmj.com/archive ↗
http://gh.bmj.com/ ↗ - DOI:
- 10.1136/bmjgh-2016-000260.69 ↗
- Languages:
- English
- ISSNs:
- 2059-7908
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17722.xml