Optical coherence tomography angiography and indocyanine green angiography for corneal vascularisation. Issue 11 (28th January 2016)
- Record Type:
- Journal Article
- Title:
- Optical coherence tomography angiography and indocyanine green angiography for corneal vascularisation. Issue 11 (28th January 2016)
- Main Title:
- Optical coherence tomography angiography and indocyanine green angiography for corneal vascularisation
- Authors:
- Ang, Marcus
Cai, Yijun
MacPhee, Becky
Sim, Dawn A
Keane, Pearse A
Sng, Chelvin C A
Egan, Catherine A
Tufail, Adnan
Larkin, Daniel F
Wilkins, Mark R - Abstract:
- Abstract : Background/Aim: To describe an optical coherence tomography angiography (OCTA) system adapted for anterior segment imaging, compared with indocyanine green angiography (ICGA) in eyes with corneal vascularisation. Methods: Retrospective study of subjects with corneal vascularisation secondary to microbial keratitis who had OCTA scans performed using a commercially available split-spectrum amplitude-decorrelation algorithm angiography system (AngioVue; Optovue Inc., Fremont, California, USA) and ICGA images (Spectralis; Heidelberg Engineering, Heidelberg, Germany). The agreement between OCTA and ICGA techniques in terms of area of vascularisation measured, using Bland–Altman 95% limits of agreement (LOA). Results: We compared the area of corneal vascularisation in 64 scan images (eight eyes, four scans for each angiography technique). In our series, the overall mean area of vascularisation from the ICGA scans was 0.49±0.34 mm 2 and OCTA scans was 0.51±0.36 mm 2 . We obtained substantial repeatability in terms of image quality score (κ=0.80) for all OCTA scans. The agreement between OCTA and ICGA scans was good, although ICGA measured a smaller area compared with the OCTA with a mean difference of −0.03 mm 2 (95% CI −0.07 to 0.01). The LOA ranged from a lower limit of −0.27 (95% CI −0.34 to −0.19) to an upper limit of 0.20 (95% CI 0.13 to 0.28, p=0.127). Conclusions: We found that rapid, non-contact OCTA adapted for the cornea was comparable with ICGA for measurementAbstract : Background/Aim: To describe an optical coherence tomography angiography (OCTA) system adapted for anterior segment imaging, compared with indocyanine green angiography (ICGA) in eyes with corneal vascularisation. Methods: Retrospective study of subjects with corneal vascularisation secondary to microbial keratitis who had OCTA scans performed using a commercially available split-spectrum amplitude-decorrelation algorithm angiography system (AngioVue; Optovue Inc., Fremont, California, USA) and ICGA images (Spectralis; Heidelberg Engineering, Heidelberg, Germany). The agreement between OCTA and ICGA techniques in terms of area of vascularisation measured, using Bland–Altman 95% limits of agreement (LOA). Results: We compared the area of corneal vascularisation in 64 scan images (eight eyes, four scans for each angiography technique). In our series, the overall mean area of vascularisation from the ICGA scans was 0.49±0.34 mm 2 and OCTA scans was 0.51±0.36 mm 2 . We obtained substantial repeatability in terms of image quality score (κ=0.80) for all OCTA scans. The agreement between OCTA and ICGA scans was good, although ICGA measured a smaller area compared with the OCTA with a mean difference of −0.03 mm 2 (95% CI −0.07 to 0.01). The LOA ranged from a lower limit of −0.27 (95% CI −0.34 to −0.19) to an upper limit of 0.20 (95% CI 0.13 to 0.28, p=0.127). Conclusions: We found that rapid, non-contact OCTA adapted for the cornea was comparable with ICGA for measurement of the area of corneal vascularisation in this pilot clinical study. Further prospective studies are required to confirm if this relatively new imaging technique may be further developed to replace invasive angiography techniques for the anterior segment. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 100:Issue 11(2016)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 100:Issue 11(2016)
- Issue Display:
- Volume 100, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 100
- Issue:
- 11
- Issue Sort Value:
- 2016-0100-0011-0000
- Page Start:
- 1557
- Page End:
- 1563
- Publication Date:
- 2016-01-28
- Subjects:
- Cornea -- Imaging -- Neovascularisation
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2015-307706 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17686.xml