Comparison of femoral stem subsidence between three types of press‐fit cementless total hip replacement in dogs. Issue 4 (21st February 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of femoral stem subsidence between three types of press‐fit cementless total hip replacement in dogs. Issue 4 (21st February 2020)
- Main Title:
- Comparison of femoral stem subsidence between three types of press‐fit cementless total hip replacement in dogs
- Authors:
- Mitchell, Megan M.
Hudson, Caleb C.
Beale, Brian S. - Abstract:
- Abstract: Objective: To compare femoral stem subsidence and determine contributing factors in dogs undergoing total hip replacement (THR) with the traditional BFX, collared BFX, and BFX lateral bolt stems. Study design: Retrospective radiographic study. Sample population: Ninety‐three dogs with 101 THR including dogs undergoing THR with a BFX lateral bolt femoral stem (n = 40), BFX collared stem (n = 21), and traditional BFX stem (n = 40). Methods: Radiographs of traditional BFX (n = 40), collared BFX (n = 21), and BFX lateral bolt (n = 40) THR performed from 2015 to 2018 were reviewed. Subsidence, canal flare index (CFI), stem canal fill (CF), stem orientation, and complications confirmed on radiographs were recorded at postoperative and recheck radiographs. Analysis of variance tests were used to compare subsidence, CFI, stem orientation, and CF. A χ 2 analysis was performed to compare complication rates between groups. Results: Subsidence was lower after placement of BFX lateral bolt stems (median, 0.24 mm; interquartile range [IQR; 1.49) compared with collared (1.27 mm [2.29]) and BFX (1.35 mm [2.26]) stems. No difference in subsidence was detected between collared and BFX implants. Coronal CF was greater after placement of BFX (mean ± SD, 0.72 ± 0.06) compared with lateral bolt (0.69 ± 0.05) or collared (0.66 ± 0.07) stems. Sagittal CF differed between all groups (BFX 0.7 ± 0.05, lateral bolt 0.67 ± 0.06, and collared 0.61 ± 0.06). No differences were identified in CFIAbstract: Objective: To compare femoral stem subsidence and determine contributing factors in dogs undergoing total hip replacement (THR) with the traditional BFX, collared BFX, and BFX lateral bolt stems. Study design: Retrospective radiographic study. Sample population: Ninety‐three dogs with 101 THR including dogs undergoing THR with a BFX lateral bolt femoral stem (n = 40), BFX collared stem (n = 21), and traditional BFX stem (n = 40). Methods: Radiographs of traditional BFX (n = 40), collared BFX (n = 21), and BFX lateral bolt (n = 40) THR performed from 2015 to 2018 were reviewed. Subsidence, canal flare index (CFI), stem canal fill (CF), stem orientation, and complications confirmed on radiographs were recorded at postoperative and recheck radiographs. Analysis of variance tests were used to compare subsidence, CFI, stem orientation, and CF. A χ 2 analysis was performed to compare complication rates between groups. Results: Subsidence was lower after placement of BFX lateral bolt stems (median, 0.24 mm; interquartile range [IQR; 1.49) compared with collared (1.27 mm [2.29]) and BFX (1.35 mm [2.26]) stems. No difference in subsidence was detected between collared and BFX implants. Coronal CF was greater after placement of BFX (mean ± SD, 0.72 ± 0.06) compared with lateral bolt (0.69 ± 0.05) or collared (0.66 ± 0.07) stems. Sagittal CF differed between all groups (BFX 0.7 ± 0.05, lateral bolt 0.67 ± 0.06, and collared 0.61 ± 0.06). No differences were identified in CFI or stem orientation in the coronal and sagittal planes or in complication rates between implants. Conclusion: The BFX lateral bolt femoral stem was associated with less postoperative subsidence compared with the BFX collared and traditional BFX stems. No consistent changes in CF, CFI, or stem orientation or complication rates were identified in association with increased subsidence in this study. Clinical significance: Implantation of a lateral bolt femoral stem should be considered during THR to prevent subsidence. … (more)
- Is Part Of:
- Veterinary surgery. Volume 49:Issue 4(2020)
- Journal:
- Veterinary surgery
- Issue:
- Volume 49:Issue 4(2020)
- Issue Display:
- Volume 49, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 49
- Issue:
- 4
- Issue Sort Value:
- 2020-0049-0004-0000
- Page Start:
- 787
- Page End:
- 793
- Publication Date:
- 2020-02-21
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.13391 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17655.xml