Variability of lung function predicts loss of asthma control following withdrawal of inhaled corticosteroid treatment. Issue 5 (30th April 2010)
- Record Type:
- Journal Article
- Title:
- Variability of lung function predicts loss of asthma control following withdrawal of inhaled corticosteroid treatment. Issue 5 (30th April 2010)
- Main Title:
- Variability of lung function predicts loss of asthma control following withdrawal of inhaled corticosteroid treatment
- Authors:
- Thamrin, Cindy
Taylor, D Robin
Jones, Stuart L
Suki, Béla
Frey, Urs - Abstract:
- Abstract : Background: One aspect of a multidimensional approach to understanding asthma as a complex dynamic disease is to study how lung function varies with time. Variability measures of lung function have been shown to predict response to β2 -agonist treatment. An investigation was conducted to determine whether mean, coefficient of variation (CV) or autocorrelation, a measure of short-term memory, of peak expiratory flow (PEF) could predict loss of asthma control following withdrawal of regular inhaled corticosteroid (ICS) treatment, using data from a previous study. Methods: 87 adult patients with mild to moderate asthma who had been taking ICS at a constant dose for at least 6 months were monitored for 2–4 weeks. ICS was then withdrawn and monitoring continued until loss of control occurred as per predefined criteria. Twice-daily PEF was recorded during monitoring. Associations between loss of control and mean, CV and autocorrelation of morning PEF within 2 weeks pre- and post-ICS withdrawal were assessed using Cox regression analysis. Predictive utility was assessed using receiver operator characteristics. Results: 53 out of 87 patients had sufficient PEF data over the required analysis period. The mean (389 vs 370 l/min, p<0.0001) and CV (4.5% vs 5.6%, p=0.007) but not autocorrelation of PEF changed significantly from prewithdrawal to postwithdrawal in subjects who subsequently lost control, and were unaltered in those who did not. These changes were related to timeAbstract : Background: One aspect of a multidimensional approach to understanding asthma as a complex dynamic disease is to study how lung function varies with time. Variability measures of lung function have been shown to predict response to β2 -agonist treatment. An investigation was conducted to determine whether mean, coefficient of variation (CV) or autocorrelation, a measure of short-term memory, of peak expiratory flow (PEF) could predict loss of asthma control following withdrawal of regular inhaled corticosteroid (ICS) treatment, using data from a previous study. Methods: 87 adult patients with mild to moderate asthma who had been taking ICS at a constant dose for at least 6 months were monitored for 2–4 weeks. ICS was then withdrawn and monitoring continued until loss of control occurred as per predefined criteria. Twice-daily PEF was recorded during monitoring. Associations between loss of control and mean, CV and autocorrelation of morning PEF within 2 weeks pre- and post-ICS withdrawal were assessed using Cox regression analysis. Predictive utility was assessed using receiver operator characteristics. Results: 53 out of 87 patients had sufficient PEF data over the required analysis period. The mean (389 vs 370 l/min, p<0.0001) and CV (4.5% vs 5.6%, p=0.007) but not autocorrelation of PEF changed significantly from prewithdrawal to postwithdrawal in subjects who subsequently lost control, and were unaltered in those who did not. These changes were related to time to loss of control. CV was the most consistent predictor, with similar sensitivity and sensitivity to exhaled nitric oxide. Conclusion: A simple, easy to obtain variability measure of daily lung function such as the CV may predict loss of asthma control within the first 2 weeks of ICS withdrawal. … (more)
- Is Part Of:
- Thorax. Volume 65:Issue 5(2010)
- Journal:
- Thorax
- Issue:
- Volume 65:Issue 5(2010)
- Issue Display:
- Volume 65, Issue 5 (2010)
- Year:
- 2010
- Volume:
- 65
- Issue:
- 5
- Issue Sort Value:
- 2010-0065-0005-0000
- Page Start:
- 403
- Page End:
- 408
- Publication Date:
- 2010-04-30
- Subjects:
- Asthma -- coefficient of variation -- lung function tests -- peak expiratory flow rate -- respiratory measurement
Chest -- Diseases -- Periodicals
Thorax
Chest -- Diseases
Periodicals
Periodicals
617.54 - Journal URLs:
- http://thorax.bmjjournals.com/contents-by-date.0.shtml ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/thx.2009.129668 ↗
- Languages:
- English
- ISSNs:
- 0040-6376
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17657.xml