Evaluation of auto‐planning in IMRT and VMAT for head and neck cancer. Issue 7 (4th July 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of auto‐planning in IMRT and VMAT for head and neck cancer. Issue 7 (4th July 2019)
- Main Title:
- Evaluation of auto‐planning in IMRT and VMAT for head and neck cancer
- Authors:
- Ouyang, Zi
Liu Shen, Zhilei
Murray, Eric
Kolar, Matt
LaHurd, Danielle
Yu, Naichang
Joshi, Nikhil
Koyfman, Shlomo
Bzdusek, Karl
Xia, Ping - Abstract:
- Abstract: Purpose: The purposes of this work are to (a) investigate whether the use of auto‐planning and multiple iterations improves quality of head and neck (HN) radiotherapy plans; (b) determine whether delivery methods such as step‐and‐shoot (SS) and volumetric modulated arc therapy (VMAT) impact plan quality; (c) report on the observations of plan quality predictions of a commercial feasibility tool. Materials and methods: Twenty HN cases were retrospectively selected from our clinical database for this study. The first ten plans were used to test setting up planning goals and other optimization parameters in the auto‐planning module. Subsequently, the other ten plans were replanned with auto‐planning using step‐and‐shoot (AP‐SS) and VMAT (AP‐VMAT) delivery methods. Dosimetric endpoints were compared between the clinical plans and the corresponding AP‐SS and AP‐VMAT plans. Finally, predicted dosimetric endpoints from a commercial program were assessed. Results: All AP‐SS and AP‐VMAT plans met the clinical dose constraints. With auto‐planning, the dose coverage of the low dose planning target volume (PTV) was improved while the dose coverage of the high dose PTV was maintained. Compared to the clinical plans, the doses to critical organs, such as the brainstem, parotid, larynx, esophagus, and oral cavity were significantly reduced in the AP‐VMAT ( P < 0.05); the AP‐SS plans had similar homogeneity indices (HI) and conformality indices (CI) and the AP‐VMAT plans hadAbstract: Purpose: The purposes of this work are to (a) investigate whether the use of auto‐planning and multiple iterations improves quality of head and neck (HN) radiotherapy plans; (b) determine whether delivery methods such as step‐and‐shoot (SS) and volumetric modulated arc therapy (VMAT) impact plan quality; (c) report on the observations of plan quality predictions of a commercial feasibility tool. Materials and methods: Twenty HN cases were retrospectively selected from our clinical database for this study. The first ten plans were used to test setting up planning goals and other optimization parameters in the auto‐planning module. Subsequently, the other ten plans were replanned with auto‐planning using step‐and‐shoot (AP‐SS) and VMAT (AP‐VMAT) delivery methods. Dosimetric endpoints were compared between the clinical plans and the corresponding AP‐SS and AP‐VMAT plans. Finally, predicted dosimetric endpoints from a commercial program were assessed. Results: All AP‐SS and AP‐VMAT plans met the clinical dose constraints. With auto‐planning, the dose coverage of the low dose planning target volume (PTV) was improved while the dose coverage of the high dose PTV was maintained. Compared to the clinical plans, the doses to critical organs, such as the brainstem, parotid, larynx, esophagus, and oral cavity were significantly reduced in the AP‐VMAT ( P < 0.05); the AP‐SS plans had similar homogeneity indices (HI) and conformality indices (CI) and the AP‐VMAT plans had comparable HI and improved CI. Good agreement in dosimetric endpoints between predictions and AP‐VMAT plans were observed in five of seven critical organs. Conclusion: With improved planning quality and efficiency, auto‐planning module is an effective tool to enable planners to generate HN IMRT plans that are meeting institution specific planning protocols. DVH prediction is feasible in improving workflow and plan quality. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 7(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 7(2019)
- Issue Display:
- Volume 20, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 7
- Issue Sort Value:
- 2019-0020-0007-0000
- Page Start:
- 39
- Page End:
- 47
- Publication Date:
- 2019-07-04
- Subjects:
- auto‐planning -- head and neck -- IMRT -- step and shoot -- VMAT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12652 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17655.xml