Value of cardiac 123I-mIBG scintigraphy in prognosis of catheter ablation outcome in patients with atrial fibrillation. (20th July 2021)
- Record Type:
- Journal Article
- Title:
- Value of cardiac 123I-mIBG scintigraphy in prognosis of catheter ablation outcome in patients with atrial fibrillation. (20th July 2021)
- Main Title:
- Value of cardiac 123I-mIBG scintigraphy in prognosis of catheter ablation outcome in patients with atrial fibrillation
- Authors:
- Sazonova, S
Varlamova, JV
Nikitin, NA
Minin, SM
Kisteneva, IV
Batalov, RE
Mishkina, AI
Ilushenkova, JN
Zavadovsky, KV
Popov, SV
Romanov, AB - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Russian Science Foundation Background. Previous studies show inconsistent results on the role of innervation imaging (with 123I-mIBG) in predicting late atrial fibrillation (AF) recurrence after catheter ablation (CA). These studies included patients with paroxysmal AF and studied prognostic value of post CA I-123-mIBG parameters. Current study investigated the ability of pre CA 123-I-mIBG imaging to predict late AF recurrence in patients with persistent AF. Thus, the goal of the present study was to estimate the utility of pre-procedural cardiac 123I-mIBG scintigraphy to identify patients at risk for AF recurrence after CA. Methods. 123I-mIBG cardiac imaging was performed before CA in 82 patients with persistent AF. Patients were followed for 12 months. A blanking period of 3 months was applied. The primary endpoint of the study was AF recurrence between 3 and 12 months after ablation. Results. Multivariable analysis demonstrated that late heart-to-mediastinum ratio (H/Mlate) and washout rate (WR) were independent predictors of AF recurrence. ROC-curve analysis data showed that H/Mlate <1.6 (sensitivity 73.53 %, specificity 81.3%, AUC 0, 792, p < 0.001) and WR > 25, 11 (sensitivity 70.6%, specificity 70.8.3%, AUC 0, 712, p < 0.001) indicate high probability of AF relapses during 12 months after CA. Kaplan-Meier analysis showed that the H/Mlate < 1.6, WR > 25, 11 and LAD > 45Abstract: Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Russian Science Foundation Background. Previous studies show inconsistent results on the role of innervation imaging (with 123I-mIBG) in predicting late atrial fibrillation (AF) recurrence after catheter ablation (CA). These studies included patients with paroxysmal AF and studied prognostic value of post CA I-123-mIBG parameters. Current study investigated the ability of pre CA 123-I-mIBG imaging to predict late AF recurrence in patients with persistent AF. Thus, the goal of the present study was to estimate the utility of pre-procedural cardiac 123I-mIBG scintigraphy to identify patients at risk for AF recurrence after CA. Methods. 123I-mIBG cardiac imaging was performed before CA in 82 patients with persistent AF. Patients were followed for 12 months. A blanking period of 3 months was applied. The primary endpoint of the study was AF recurrence between 3 and 12 months after ablation. Results. Multivariable analysis demonstrated that late heart-to-mediastinum ratio (H/Mlate) and washout rate (WR) were independent predictors of AF recurrence. ROC-curve analysis data showed that H/Mlate <1.6 (sensitivity 73.53 %, specificity 81.3%, AUC 0, 792, p < 0.001) and WR > 25, 11 (sensitivity 70.6%, specificity 70.8.3%, AUC 0, 712, p < 0.001) indicate high probability of AF relapses during 12 months after CA. Kaplan-Meier analysis showed that the H/Mlate < 1.6, WR > 25, 11 and LAD > 45 mm significantly increase the risk of AF recurrence after CA (p < 0.001, p < 0.001, p < 0.025 respectively). Conclusion. Pre CA parameters of global cardiac sympathetic activity estimated by 123I-mIBG scintigraphy are associated with late AF relapses in persistent AF patients. … (more)
- Is Part Of:
- European heart journal. Volume 22(2021)Supplement 3
- Journal:
- European heart journal
- Issue:
- Volume 22(2021)Supplement 3
- Issue Display:
- Volume 22, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2021-0022-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07-20
- Subjects:
- Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeab111.081 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17659.xml