Analysis of the 2010–2012 results of the multicenter external proficiency study for 25-hydroxyvitamin D. (October 2013)
- Record Type:
- Journal Article
- Title:
- Analysis of the 2010–2012 results of the multicenter external proficiency study for 25-hydroxyvitamin D. (October 2013)
- Main Title:
- Analysis of the 2010–2012 results of the multicenter external proficiency study for 25-hydroxyvitamin D
- Authors:
- Bianchi, Sara
Giovannini, Stefania
Zucchelli, Giancarlo
Clerico, Aldo
Pierini, Martina
Ndreu, Rudina
Vannucci, Alessandro
Battaglia, Debora
Vassalle, Cristina - Abstract:
- Background: Results collected from the 2010–2012 cycles of the 'Immunocheck' external quality assessment scheme for 25-hydroxyvitamin D, conducted by QualiMedLab CNR (Italy) and ProBioQual (France; 250 among Italian and French laboratories) are presented in this article.Methods: Details of how QualiMedLab operates can be found in QualiMedLab website.Results: Interlaboratory imprecision was 19 (2010), 15 (2011) and 13% (2012). The LIAISON ® analyzer (DiaSorin, Italy) was the most utilized, followed by Roche (UK), ImmunoDiagnostic Systems methods (UK), ARCHITECT (Abbott, IL, USA), radioimmunoassay (DiaSorin) and others. The within-method variability between laboratories (percentage coefficient of variation) were 15, 12.7 versus 9.8% for LIAISON, 27.8, 16.5 versus 11.7% for Roche, 15, 12 versus 17% for ImmunoDiagnostic Systems and 17.4, 18.6 versus 17.5% for radioimmunoassay in the 2010, 2011 versus 2012 cycles, and 15 versus 8.9% for ARCHITECT in the 2011 versus 2012, respectively.Conclusion: Significant differences in specific samples and discrepancies between laboratories and methods still exist, making the actuation of appropriate external quality assessment schemes mandatory.
- Is Part Of:
- Biomarkers in medicine. Volume 7:Number 5(2013)
- Journal:
- Biomarkers in medicine
- Issue:
- Volume 7:Number 5(2013)
- Issue Display:
- Volume 7, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 7
- Issue:
- 5
- Issue Sort Value:
- 2013-0007-0005-0000
- Page Start:
- 691
- Page End:
- 699
- Publication Date:
- 2013-10
- Subjects:
- 25-hydroxyvitamin D -- external quality assessment -- external quality schemes -- methods -- quality assessment
Biochemical markers -- Periodicals
610.28 - Journal URLs:
- http://www.futuremedicine.com/loi/bmm ↗
http://www.futuremedicine.com/ ↗ - DOI:
- 10.2217/bmm.13.72 ↗
- Languages:
- English
- ISSNs:
- 1752-0363
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.704700
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 17637.xml