Pump position and thrombosis in ventricular assist devices: Correlation of radiographs and CT data. Issue 12 (December 2021)
- Record Type:
- Journal Article
- Title:
- Pump position and thrombosis in ventricular assist devices: Correlation of radiographs and CT data. Issue 12 (December 2021)
- Main Title:
- Pump position and thrombosis in ventricular assist devices: Correlation of radiographs and CT data
- Authors:
- Aigner, Philipp
Schlöglhofer, Thomas
Plunger, Lea Carmen
Beitzke, Dietrich
Wielandner, Alice
Schima, Heinrich
Zimpfer, Daniel
Moscato, Francesco - Abstract:
- Malpositioning of left ventricular assist devices (LVAD) is a risk factor for thrombosis, but its identification from clinical imaging remains challenging. X-rays and CT scans were analyzed and parameters identified that correlated to pump thrombosis. Retrospective imaging data of patients ( n = 115) with HeartmateII (HMII) or HVAD were analyzed in two groups (pump-thrombosis PT, n = 15 vs matched control group NT, n = 15) using routine X-rays and CT scans. In CT, directional deviations of the inflow cannula in three-chamber and two-chamber view (α and β angles) were identified. In HVAD PT frontal radiographs showed reduced pump body area and smaller minor axis (PT 41.3 ± 4.8 mm vs NT 34.9 ± 6.0 mm, p = 0.026), and in the lateral radiographs the visibility of the inflow cannula served as a predictive parameter for PT. In HMII patients, no parameters were associated with PT. The angle α differed significantly (NT −1.2 ± 7.5°, PT −22.0 ± 4.7°, p = 0.006) in HVAD patients. Further, correlations of x-ray parameters with CT angles α and β showed that radiographs can be used to identify malpositioned pumps. Well-aligned inflow cannula positions are essential. HVAD patients with a posterior rotation of the inflow cannula have a higher risk of pump thrombosis. This risk can reliably be identified from routine radiographs.
- Is Part Of:
- International journal of artificial organs. Volume 44:Issue 12(2021)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 44:Issue 12(2021)
- Issue Display:
- Volume 44, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 12
- Issue Sort Value:
- 2021-0044-0012-0000
- Page Start:
- 956
- Page End:
- 964
- Publication Date:
- 2021-12
- Subjects:
- LVAD pump thrombosis -- inflow cannula position -- radiographs -- CT scan
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.1177/03913988211017552 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17617.xml