Enhancing the efficacy of the 20 m multistage shuttle run test. Issue 3 (23rd February 2005)
- Record Type:
- Journal Article
- Title:
- Enhancing the efficacy of the 20 m multistage shuttle run test. Issue 3 (23rd February 2005)
- Main Title:
- Enhancing the efficacy of the 20 m multistage shuttle run test
- Authors:
- Flouris, A D
Metsios, G S
Koutedakis, Y - Abstract:
- Abstract : Objective: Maximal oxygen uptake (Vo2max ) of 44 ml kg −1 min −1 is an accepted criterion (Vo2CR ) below which health and fitness for young male adults may be compromised. New algorithms validated for Vo2CR screening using the 20 m multistage shuttle run test (20mMST) were developed. Methods: Vo2max was assessed in 110 males using a stationary gas analyser in a treadmill test (TT) and in 40 of these subjects using a portable gas analyser in the 20mMST. Vo2max predicted from the 20mMST in 70 subjects was used for cross validation. Two equations predicting Vo2max during 20mMST (EQMST ) and TT (EQTT ) were developed. Results: Significant energy cost variance (ECV ) was detected between TT and 20mMST (p<0.001), correlated significantly with subject height, and was a significant predictor of Vo2max differences between TT and 20mMST. The r 2 of EQMST was 0.92 (p<0.001). Predicted Vo2max values from EQMST correlated with directly measured 20mMST Vo2max at r = 0.96 (p<0.001). ANOVA detected no mean difference (p>0.05) between predicted and measured values. Prevalence of low fitness based on Vo2CR was 0.37. McNemar χ 2 indicated significant differences in sensitivity (p<0.001) and specificity (p<0.05) between the original 20mMST equation (EQLÉG ) and EQTT, regarding Vo2CR screening. Cohen's κ demonstrated higher agreement with TT Vo2max for EQTT (p<0.001) than EQLÉG (p<0.05). TT Vo2max correlated with the end result of both EQLÉG and EQTT at r = 0.75 (p<0.001). UnlikeAbstract : Objective: Maximal oxygen uptake (Vo2max ) of 44 ml kg −1 min −1 is an accepted criterion (Vo2CR ) below which health and fitness for young male adults may be compromised. New algorithms validated for Vo2CR screening using the 20 m multistage shuttle run test (20mMST) were developed. Methods: Vo2max was assessed in 110 males using a stationary gas analyser in a treadmill test (TT) and in 40 of these subjects using a portable gas analyser in the 20mMST. Vo2max predicted from the 20mMST in 70 subjects was used for cross validation. Two equations predicting Vo2max during 20mMST (EQMST ) and TT (EQTT ) were developed. Results: Significant energy cost variance (ECV ) was detected between TT and 20mMST (p<0.001), correlated significantly with subject height, and was a significant predictor of Vo2max differences between TT and 20mMST. The r 2 of EQMST was 0.92 (p<0.001). Predicted Vo2max values from EQMST correlated with directly measured 20mMST Vo2max at r = 0.96 (p<0.001). ANOVA detected no mean difference (p>0.05) between predicted and measured values. Prevalence of low fitness based on Vo2CR was 0.37. McNemar χ 2 indicated significant differences in sensitivity (p<0.001) and specificity (p<0.05) between the original 20mMST equation (EQLÉG ) and EQTT, regarding Vo2CR screening. Cohen's κ demonstrated higher agreement with TT Vo2max for EQTT (p<0.001) than EQLÉG (p<0.05). TT Vo2max correlated with the end result of both EQLÉG and EQTT at r = 0.75 (p<0.001). Unlike EQTT (p>0.05), mean predicted Vo2max from EQLÉG was significantly higher compared to TT Vo2max (p<0.001). Conclusion: These algorithms increase the efficacy of 20mMST to accurately evaluate aspects of health and fitness. … (more)
- Is Part Of:
- British journal of sports medicine. Volume 39:Issue 3(2005)
- Journal:
- British journal of sports medicine
- Issue:
- Volume 39:Issue 3(2005)
- Issue Display:
- Volume 39, Issue 3 (2005)
- Year:
- 2005
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2005-0039-0003-0000
- Page Start:
- 166
- Page End:
- 170
- Publication Date:
- 2005-02-23
- Subjects:
- ANOVA, analysis of variance -- CF, cardiorespiratory fitness -- CI, confidence interval -- CV, coefficient of variation -- EC, energy cost -- GEE, generalised estimating equations -- GLM, general linear model -- LIMAG, limits of agreement analysis -- MAS, maximal attained speed -- ROC, receiver operating characteristics -- SD, standard deviation -- TT, treadmill test -- 20mMST, 20 m multistage shuttle run test
energy cost -- field testing -- receiver operating characteristics -- screening -- Vo2max
Sports medicine -- Periodicals
617.1027 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bjsm.bmj.com/ ↗ - DOI:
- 10.1136/bjsm.2004.012500 ↗
- Languages:
- English
- ISSNs:
- 0306-3674
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17604.xml