Wear Behavior of an Unstable Knee: Stabilization via Implant Design?. (9th September 2014)
- Record Type:
- Journal Article
- Title:
- Wear Behavior of an Unstable Knee: Stabilization via Implant Design?. (9th September 2014)
- Main Title:
- Wear Behavior of an Unstable Knee: Stabilization via Implant Design?
- Authors:
- Reinders, Jörn
Sonntag, Robert
Kretzer, Jan Philippe - Other Names:
- Grupp Thomas M. Academic Editor.
- Abstract:
- Abstract : Background . Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods . Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results . Significantly higher wear rates (P ≤ 0.001 ) were observed for the unstable knee (14.58 ± 0.56 mg/10 6 cycles) compared to the stable knee (7.97 ± 0.87 mg/10 6 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01 ). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion . Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear wasAbstract : Background . Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods . Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results . Significantly higher wear rates (P ≤ 0.001 ) were observed for the unstable knee (14.58 ± 0.56 mg/10 6 cycles) compared to the stable knee (7.97 ± 0.87 mg/10 6 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01 ). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion . Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study. … (more)
- Is Part Of:
- BioMed research international. Volume 2014(2014)
- Journal:
- BioMed research international
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-09-09
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2014/821475 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17586.xml