P25 Comparison of renal function estimation methods in critically ill children: a pilot study. Issue 6 (17th May 2019)
- Record Type:
- Journal Article
- Title:
- P25 Comparison of renal function estimation methods in critically ill children: a pilot study. Issue 6 (17th May 2019)
- Main Title:
- P25 Comparison of renal function estimation methods in critically ill children: a pilot study
- Authors:
- Dhont, E
Van Der Heggen, T
De Jaeger, A
Willems, J
De Baere, S
Croubels, S
Vande Walle, J
De Paepe, P
De Cock, P - Abstract:
- Abstract : Background: Accurate assessment of renal function is crucial in intensive care to guide therapy. Both acute kidney injury and augmented renal clearance (ARC) may compromise outcome. Common formulas to estimate glomerular filtration rate (GFR) are unreliable in critically ill adults. 1 A comparison of a gold standard technique to assess GFR with these formula-based estimations has never been reported in pediatric intensive care (PICU) patients. Our aim was to evaluate the feasibility of measuring plasma iohexol clearance (CLIOHEX ) for GFR assessment in critically ill children and to compare CLIOHEX with estimated GFR using the modified Schwartz formula (eGFRSchwartz ). Methods: A prospective, interventional study was conducted at the PICU of the Ghent University Hospital, Belgium. Critically ill children without chronic kidney disease were included. After injection of a weight-dependent bolus of iohexol, serial blood samples (n=6) were taken over a 6-hours interval. CLIOHEX was compared to eGFRSchwartz . Correlation between both methods was assessed by a Pearson´s correlation coefficient (r).Bland-Altman plots were evaluated to assess bias and limits of agreement (LOA). ARC was defined as a GFR exceeding normal values for age plus two standard deviations. Results: 40 patients, median age 16 months (range 15 days -13, 6 years), 72, 5% males, were included. No adverse effects related to iohexol were observed. Median CLIOHEX was 121 ml/min/1.73m 2 (range: 43–221Abstract : Background: Accurate assessment of renal function is crucial in intensive care to guide therapy. Both acute kidney injury and augmented renal clearance (ARC) may compromise outcome. Common formulas to estimate glomerular filtration rate (GFR) are unreliable in critically ill adults. 1 A comparison of a gold standard technique to assess GFR with these formula-based estimations has never been reported in pediatric intensive care (PICU) patients. Our aim was to evaluate the feasibility of measuring plasma iohexol clearance (CLIOHEX ) for GFR assessment in critically ill children and to compare CLIOHEX with estimated GFR using the modified Schwartz formula (eGFRSchwartz ). Methods: A prospective, interventional study was conducted at the PICU of the Ghent University Hospital, Belgium. Critically ill children without chronic kidney disease were included. After injection of a weight-dependent bolus of iohexol, serial blood samples (n=6) were taken over a 6-hours interval. CLIOHEX was compared to eGFRSchwartz . Correlation between both methods was assessed by a Pearson´s correlation coefficient (r).Bland-Altman plots were evaluated to assess bias and limits of agreement (LOA). ARC was defined as a GFR exceeding normal values for age plus two standard deviations. Results: 40 patients, median age 16 months (range 15 days -13, 6 years), 72, 5% males, were included. No adverse effects related to iohexol were observed. Median CLIOHEX was 121 ml/min/1.73m 2 (range: 43–221 ml/min/1.73m 2 ). ARC was present in 20 patients based on CLIOHEX . Median eGFRSchwartz was 81 ml/min/1.73m 2 (range: 31–131 ml/min/1.73m 2 ). Only 1 patient was identified with ARC by eGFRSchwartz . eGFRSchwartz was systematically lower than CLIOHEX . There was a good correlation between CLIOHEX and eGFRSchwartz (r = 0, 69; p< 0, 01). Bias was 34 ml/min/1.73m 2 with LOA (-24, 5; 93 ml/min/1.73m 2 ) Conclusion: CLIOHEX was safely used to measure true GFR in critically ill children. eGFRSchwartz systematically underestimates GFR, especially in patients with ARC and seems not reliable in this patient population. Reference: Baptista JP, Neves M, Rodrigues L, Teixeira L, Pinho J, Pimentel J ( 2014) Accuracy of the estimation of glomerular filtration rate within a population of critically ill patients. J Nephrol . 27:403–410. Disclosure(s): Nothing to disclose … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 104:Issue 6(2019)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 104:Issue 6(2019)
- Issue Display:
- Volume 104, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 104
- Issue:
- 6
- Issue Sort Value:
- 2019-0104-0006-0000
- Page Start:
- e27
- Page End:
- e27
- Publication Date:
- 2019-05-17
- Subjects:
- Children -- Diseases -- Periodicals
Infants -- Diseases -- Periodicals
618.920005 - Journal URLs:
- http://adc.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2019-esdppp.63 ↗
- Languages:
- English
- ISSNs:
- 0003-9888
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17591.xml