Accuracy of optical coherence tomography imaging in assessing aneurysmal remnants after flow diversion. (2nd June 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of optical coherence tomography imaging in assessing aneurysmal remnants after flow diversion. (2nd June 2020)
- Main Title:
- Accuracy of optical coherence tomography imaging in assessing aneurysmal remnants after flow diversion
- Authors:
- Fries, Frederik
Maßmann, Alexander
Tomori, Toshiki
Yilmaz, Umut
Kettner, Michael
Simgen, Andreas
Cattaneo, Giorgio
Wagenpfeil, Gudrun
Reith, Wolfgang
Mühl-Benninghaus, Ruben - Abstract:
- Abstract : Background: Optical coherence tomography (OCT) is an ultra-high resolution real-time intravascular imaging method that is gaining interest in cerebrovascular applications. Objective: To compare, in a rabbit elastase aneurysm model, digital subtraction angiography (DSA) and OCT as diagnostic tools for the assessment of aneurysmal remnants and baseline characteristics of aneurysms after flow diverter (FD) implantation. Methods: With Institutional Animal Care and Use Committee approval, saccular aneurysms were created in 28 rabbits and treated with Derivo FDs. DSA was performed before, and immediately after, stent implantation. As a follow-up, DSA and OCT were performed 28 days after device implantation. Results: DSA and OCT were successfully performed in 23 cases. OCT could not be achieved in 5 cases owing to navigational difficulties in the stent lumen with the OCT catheter. Residual aneurysms were significantly more often visible with OCT (18/23 (78%) than with DSA 12/23 (52%), p = 0.031). Conclusion: OCT was more sensitive than conventional angiography for the assessment of residual aneurysms at 28 days after FD implantation in an animal model.
- Is Part Of:
- Journal of neurointerventional surgery. Volume 12:Number 12(2020)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 12:Number 12(2020)
- Issue Display:
- Volume 12, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 12
- Issue Sort Value:
- 2020-0012-0012-0000
- Page Start:
- 1242
- Page End:
- 1246
- Publication Date:
- 2020-06-02
- Subjects:
- flow diverter -- aneurysm -- neck -- angiography -- stent
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2020-016129 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17589.xml