Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study. Issue 6 (12th September 2020)
- Record Type:
- Journal Article
- Title:
- Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study. Issue 6 (12th September 2020)
- Main Title:
- Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study
- Authors:
- Goossens, Quentin
Pastrav, Leonard
Roosen, Jorg
Mulier, Michiel
Desmet, Wim
Vander Sloten, Jos
Denis, Kathleen - Abstract:
- Abstract: The initial stability of cementless total hip arthroplasty (THA) implants is obtained by an interference fit that allows osseointegration for a long term secondary stability of the implant. Yet, finding the insertion endpoint that corresponds to an appropriate initial stability is currently often based on a number of subjective experiences of the orthopedic surgeon, which can be challenging. In order to assist the orthopedic surgeons in their pursuit to find this optimal initial stability, this study aims to determine whether the analysis of sound that results from the implant insertion hammer blows can be used to objectively monitor the insertion process of cementless THA implants. An in vivo study was conducted. The experimental results revealed vibro‐acoustic behavior sensitive to implant seating, related to the low frequency content of the response spectra. This sensitive low‐frequency behavior was quantified by a set of specific vibro‐acoustic features and metrics that reflected the power and similarity of the low‐frequency response. These features and metrics allowed monitoring the implant seating and their convergence agreed well with the endpoint of insertion as determined by the orthopedic surgeon. Intraoperative fractures caused an abrupt and opposite change of the vibro‐acoustic behavior prior to the notification of the fracture by the orthopedic surgeon. The observation of such an abrupt change in the vibro‐acoustic behavior can be an important earlyAbstract: The initial stability of cementless total hip arthroplasty (THA) implants is obtained by an interference fit that allows osseointegration for a long term secondary stability of the implant. Yet, finding the insertion endpoint that corresponds to an appropriate initial stability is currently often based on a number of subjective experiences of the orthopedic surgeon, which can be challenging. In order to assist the orthopedic surgeons in their pursuit to find this optimal initial stability, this study aims to determine whether the analysis of sound that results from the implant insertion hammer blows can be used to objectively monitor the insertion process of cementless THA implants. An in vivo study was conducted. The experimental results revealed vibro‐acoustic behavior sensitive to implant seating, related to the low frequency content of the response spectra. This sensitive low‐frequency behavior was quantified by a set of specific vibro‐acoustic features and metrics that reflected the power and similarity of the low‐frequency response. These features and metrics allowed monitoring the implant seating and their convergence agreed well with the endpoint of insertion as determined by the orthopedic surgeon. Intraoperative fractures caused an abrupt and opposite change of the vibro‐acoustic behavior prior to the notification of the fracture by the orthopedic surgeon. The observation of such an abrupt change in the vibro‐acoustic behavior can be an important early warning for loss of implant stability. The presented vibro‐acoustic measurement method shows potential to serve as a decision supporting source of information as it showed to reflect the implant seating. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 39:Issue 6(2021)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 39:Issue 6(2021)
- Issue Display:
- Volume 39, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 39
- Issue:
- 6
- Issue Sort Value:
- 2021-0039-0006-0000
- Page Start:
- 1164
- Page End:
- 1173
- Publication Date:
- 2020-09-12
- Subjects:
- cementless total hip arthroplasty -- primary implant stability -- vibro‐acoustic analysis
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.24837 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17584.xml