Real-world clinical performance of commercial SARS-CoV-2 rapid antigen tests in suspected COVID-19: A systematic meta-analysis of available data as of November 20, 2020. (July 2021)
- Record Type:
- Journal Article
- Title:
- Real-world clinical performance of commercial SARS-CoV-2 rapid antigen tests in suspected COVID-19: A systematic meta-analysis of available data as of November 20, 2020. (July 2021)
- Main Title:
- Real-world clinical performance of commercial SARS-CoV-2 rapid antigen tests in suspected COVID-19: A systematic meta-analysis of available data as of November 20, 2020
- Authors:
- Hayer, Johannes
Kasapic, Dusanka
Zemmrich, Claudia - Abstract:
- Graphical abstract: Highlights: Rapid antigen tests (RATs) can aid diagnosis of SARS-CoV-2 infection. RAT sensitivity ranged from 28.9% (95% CI 16.4–44.3) to 98.3% (95% CI 91.1–99.7). RAT specificity ranged from 45% (95% CI 23.1–68.5) to 100% (95% CI 99.7–100). RAT sensitivity was improved in samples with high viral loads (low Ct). Data support the use of rapid antigen tests in high-viral-load populations. Abstract: Objectives: Rapid antigen tests, or RATs, are a type of lateral flow chromatographic immunoassay utilized to aid the diagnosis of SARS-CoV-2 infection. We performed a systematic meta-analysis to compare the real-world performance of commercially available RATs. Methods: We searched several databases and websites for manufacturer-independent prospective clinical performance studies comparing SARS-CoV-2 RATs and RT-PCR. Only studies on RATs that did not need a separate reader for result retrieval and that reported data on viral load, patients' symptom status, sample type, and PCR assay used were included. Results: 19 studies utilizing 11, 109 samples with 2, 509 RT-PCR-positives were included. RAT sensitivity varied between 28.9% (95% CI 16.4–44.3) and 98.3% (95% CI 91.1–99.7), likely dependent upon population characteristics, viral load, and symptom status. RAT specificity varied between 92.4% (95% CI 87.4–95.9) and 100% (95% CI 99.7–100) with one outlier. The RATs by Roche Diagnostics/SD Biosensor and Abbott had the highest pooled sensitivity (82.4% [95% CIGraphical abstract: Highlights: Rapid antigen tests (RATs) can aid diagnosis of SARS-CoV-2 infection. RAT sensitivity ranged from 28.9% (95% CI 16.4–44.3) to 98.3% (95% CI 91.1–99.7). RAT specificity ranged from 45% (95% CI 23.1–68.5) to 100% (95% CI 99.7–100). RAT sensitivity was improved in samples with high viral loads (low Ct). Data support the use of rapid antigen tests in high-viral-load populations. Abstract: Objectives: Rapid antigen tests, or RATs, are a type of lateral flow chromatographic immunoassay utilized to aid the diagnosis of SARS-CoV-2 infection. We performed a systematic meta-analysis to compare the real-world performance of commercially available RATs. Methods: We searched several databases and websites for manufacturer-independent prospective clinical performance studies comparing SARS-CoV-2 RATs and RT-PCR. Only studies on RATs that did not need a separate reader for result retrieval and that reported data on viral load, patients' symptom status, sample type, and PCR assay used were included. Results: 19 studies utilizing 11, 109 samples with 2, 509 RT-PCR-positives were included. RAT sensitivity varied between 28.9% (95% CI 16.4–44.3) and 98.3% (95% CI 91.1–99.7), likely dependent upon population characteristics, viral load, and symptom status. RAT specificity varied between 92.4% (95% CI 87.4–95.9) and 100% (95% CI 99.7–100) with one outlier. The RATs by Roche Diagnostics/SD Biosensor and Abbott had the highest pooled sensitivity (82.4% [95% CI 74.2–88.4] and 76.9% [95% CI 72.1–81.2], respectively). Sensitivity in high-viral-load samples (cycle threshold ≤25) showed heterogeneity among the different RATs. Conclusion: The RATs offered by Roche Diagnostics/SD Biosensor and Abbott provide sufficient manufacturer-independent, real-world performance data to support their use to detect current SARS-CoV-2 infection, particularly in high-viral-load populations. … (more)
- Is Part Of:
- International journal of infectious diseases. Volume 108(2021)
- Journal:
- International journal of infectious diseases
- Issue:
- Volume 108(2021)
- Issue Display:
- Volume 108, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 108
- Issue:
- 2021
- Issue Sort Value:
- 2021-0108-2021-0000
- Page Start:
- 592
- Page End:
- 602
- Publication Date:
- 2021-07
- Subjects:
- COVID-19 -- SARS-CoV-2 -- Rapid antigen test -- Point-of-care testing -- Immunoassay -- Lateral flow
Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
Electronic journals
616.9 - Journal URLs:
- http://bibpurl.oclc.org/web/73769 ↗
http://www.journals.elsevier.com/international-journal-of-infectious-diseases/ ↗
http://www.sciencedirect.com/science/journal/12019712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/12019712 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/12019712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijid.2021.05.029 ↗
- Languages:
- English
- ISSNs:
- 1201-9712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.304750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17594.xml