Testicular shape, scrotal skin thickness and testicular artery blood flow changes in bulls of different ages. Issue 7 (18th May 2021)
- Record Type:
- Journal Article
- Title:
- Testicular shape, scrotal skin thickness and testicular artery blood flow changes in bulls of different ages. Issue 7 (18th May 2021)
- Main Title:
- Testicular shape, scrotal skin thickness and testicular artery blood flow changes in bulls of different ages
- Authors:
- Claus, Luís Afonso Marques
Barca Junior, Flávio Antônio
Junior, Celso Koetz
Pereira, Gabriel Ribas
Fávaro, Patrícia da Cruz
Ferreira, Fabio Procópio
Galdioli, Victor Hugo Gonçalves
Seneda, Marcelo Marcondes
Ribeiro, Edson Luís de Azambuja - Abstract:
- Abstract: The aim of this study was to compare the biometric testicular characteristics, skin thickness and haemodynamics of the testicular artery of 12‐ and 24‐month‐old bulls using Doppler ultrasonography, the study was conducted using 48 indicus‐taurus animals. The scrotal circumference (SC) and biometry characteristics of the bulls were measured to calculate the testicular volume. Doppler ultrasonography was used to obtain the haemodynamic values of the testicular artery. The skin thickness and volume were lower ( p <.01) in the younger bulls (12 months:4.68 ± 0.68 mm; 168.76 ± 47.96 cm 3 ) versus 24 months (5.05 ± 0.89; 499.73 ± 129.24 cm 3 ) animals ( p <.01). During diastole, mean velocity was lower in the 12 months (7.98 ± 3.83) than in the 24 months (11.37 ± 4.15) animals ( p <.05). The 12‐month‐old animals had higher pulsatility and resistivity indices (0.49 ± 0.02; 0.51 ± 0.20) compared to the 24‐month‐old animals (0.32 ± 0.16; 0.40 ± 0.15) ( p < .05). The final testicular end velocity was lower in animals with long/moderate‐shaped (L/M) (7.31 ± 2.91) than in those moderate/oval‐shaped (M/O) (11.48 ± 3.88) testicles ( p < .05). Animals with L/M testes presented higher pulsatility values and resistivity indices (0.51 ± 0.05; 0.55 ± 0.04) compared to animals with M/O shape (0.29 ± 0.20; 0.36 ± 0.15). We showed that the blood flow of the supra testicular artery between the two evaluated ages differed, and that 24‐month‐old bulls presented better thermoregulationAbstract: The aim of this study was to compare the biometric testicular characteristics, skin thickness and haemodynamics of the testicular artery of 12‐ and 24‐month‐old bulls using Doppler ultrasonography, the study was conducted using 48 indicus‐taurus animals. The scrotal circumference (SC) and biometry characteristics of the bulls were measured to calculate the testicular volume. Doppler ultrasonography was used to obtain the haemodynamic values of the testicular artery. The skin thickness and volume were lower ( p <.01) in the younger bulls (12 months:4.68 ± 0.68 mm; 168.76 ± 47.96 cm 3 ) versus 24 months (5.05 ± 0.89; 499.73 ± 129.24 cm 3 ) animals ( p <.01). During diastole, mean velocity was lower in the 12 months (7.98 ± 3.83) than in the 24 months (11.37 ± 4.15) animals ( p <.05). The 12‐month‐old animals had higher pulsatility and resistivity indices (0.49 ± 0.02; 0.51 ± 0.20) compared to the 24‐month‐old animals (0.32 ± 0.16; 0.40 ± 0.15) ( p < .05). The final testicular end velocity was lower in animals with long/moderate‐shaped (L/M) (7.31 ± 2.91) than in those moderate/oval‐shaped (M/O) (11.48 ± 3.88) testicles ( p < .05). Animals with L/M testes presented higher pulsatility values and resistivity indices (0.51 ± 0.05; 0.55 ± 0.04) compared to animals with M/O shape (0.29 ± 0.20; 0.36 ± 0.15). We showed that the blood flow of the supra testicular artery between the two evaluated ages differed, and that 24‐month‐old bulls presented better thermoregulation capacity. Animals with a long/moderate testicular format presented a greater vascular resistance, which was imposed on the blood flow due to the anatomical differences in the testicular artery, resulting in lower velocity, and indicating better heat dissipation in this format. … (more)
- Is Part Of:
- Reproduction in domestic animals. Volume 56:Issue 7(2021)
- Journal:
- Reproduction in domestic animals
- Issue:
- Volume 56:Issue 7(2021)
- Issue Display:
- Volume 56, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 7
- Issue Sort Value:
- 2021-0056-0007-0000
- Page Start:
- 1034
- Page End:
- 1039
- Publication Date:
- 2021-05-18
- Subjects:
- biometry -- Doppler ultrasonography -- spermatic cord -- testicular blood flow -- testicular thermoregulation -- vascular resistance
Animal breeding -- Periodicals
Veterinary pathology -- Periodicals
Livestock -- Breeding -- Periodicals
636.082 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/rda.13947 ↗
- Languages:
- English
- ISSNs:
- 0936-6768
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7713.599600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17579.xml