Three‐dimensional microvascular network reconstruction from in vivo images with adaptation of the regional inhomogeneity in the signal‐to‐noise ratio. (18th May 2021)
- Record Type:
- Journal Article
- Title:
- Three‐dimensional microvascular network reconstruction from in vivo images with adaptation of the regional inhomogeneity in the signal‐to‐noise ratio. (18th May 2021)
- Main Title:
- Three‐dimensional microvascular network reconstruction from in vivo images with adaptation of the regional inhomogeneity in the signal‐to‐noise ratio
- Authors:
- Sugashi, Takuma
Yuki, Hiroya
Niizawa, Tomoya
Takuwa, Hiroyuki
Kanno, Iwao
Masamoto, Kazuto - Abstract:
- Abstract: Objective: Quantification of angiographic images with two‐photon laser scanning fluorescence microscopy (2PLSM) relies on proper segmentation of the vascular images. However, the images contain inhomogeneities in the signal‐to‐noise ratio (SNR) arising from regional effects of light scattering and absorption. The present study developed a semiautomated quantification method for volume images of 2PLSM angiography by adjusting the binarization threshold according to local SNR along the vessel centerlines. Methods: A phantom model made with fluorescent microbeads was used to incorporate a region‐dependent binarization threshold. Results: The recommended SNR for imaging was found to be 4.2–10.6 that provide the true size of imaged objects if the binarization threshold was fixed at 50% of SNR. However, angiographic images in the mouse cortex showed variable SNR up to 45 over the depths. To minimize the errors caused by variable SNR and a spatial extent of the imaged objects in an axial direction, the microvascular networks were three‐dimensionally reconstructed based on the cross‐sectional diameters measured along the vessel centerline from the XY‐plane images with adapted binarization threshold. The arterial volume was relatively constant over depths of 0–500 µm, and the capillary volume (1.7% relative to the scanned volume) showed the larger volumes than the artery (0.8%) and vein (0.6%). Conclusions: The present methods allow consistent segmentation ofAbstract: Objective: Quantification of angiographic images with two‐photon laser scanning fluorescence microscopy (2PLSM) relies on proper segmentation of the vascular images. However, the images contain inhomogeneities in the signal‐to‐noise ratio (SNR) arising from regional effects of light scattering and absorption. The present study developed a semiautomated quantification method for volume images of 2PLSM angiography by adjusting the binarization threshold according to local SNR along the vessel centerlines. Methods: A phantom model made with fluorescent microbeads was used to incorporate a region‐dependent binarization threshold. Results: The recommended SNR for imaging was found to be 4.2–10.6 that provide the true size of imaged objects if the binarization threshold was fixed at 50% of SNR. However, angiographic images in the mouse cortex showed variable SNR up to 45 over the depths. To minimize the errors caused by variable SNR and a spatial extent of the imaged objects in an axial direction, the microvascular networks were three‐dimensionally reconstructed based on the cross‐sectional diameters measured along the vessel centerline from the XY‐plane images with adapted binarization threshold. The arterial volume was relatively constant over depths of 0–500 µm, and the capillary volume (1.7% relative to the scanned volume) showed the larger volumes than the artery (0.8%) and vein (0.6%). Conclusions: The present methods allow consistent segmentation of microvasculature by adapting the local inhomogeneity in the SNR, which will be useful for quantitative comparison of the microvascular networks, such as under disease conditions where SNR in the 2PLSM images varies over space and time. … (more)
- Is Part Of:
- Microcirculation. Volume 28:Number 5(2021)
- Journal:
- Microcirculation
- Issue:
- Volume 28:Number 5(2021)
- Issue Display:
- Volume 28, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 28
- Issue:
- 5
- Issue Sort Value:
- 2021-0028-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-05-18
- Subjects:
- cerebral microcirculation -- chronic animal experiments -- optical imaging -- repeated angiography -- three‐dimensional image reconstruction
Biological transport -- Periodicals
Microcirculation -- Physiology -- Periodicals
612.135 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1549-8719/issues ↗
http://onlinelibrary.wiley.com/ ↗
http://informahealthcare.com/loi/mic ↗ - DOI:
- 10.1111/micc.12697 ↗
- Languages:
- English
- ISSNs:
- 1073-9688
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5758.460000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17553.xml