Prediction of gastric fluid volume by ultrasonography in infants undergoing general anaesthesia. (August 2021)
- Record Type:
- Journal Article
- Title:
- Prediction of gastric fluid volume by ultrasonography in infants undergoing general anaesthesia. (August 2021)
- Main Title:
- Prediction of gastric fluid volume by ultrasonography in infants undergoing general anaesthesia
- Authors:
- Kim, Eun-Hee
Yoon, Hee-Chul
Lee, Ji-Hyun
Kim, Hee-Soo
Jang, Young-Eun
Ji, Sang-Hwan
Cho, Sung-Ae
Kim, Jin-Tae - Abstract:
- Abstract: Background: Point-of-care ultrasonography can estimate gastric contents and volume to assess the risk of pulmonary aspiration; however, its use in infants has not been well validated. We aimed to develop a predictive model for estimating gastric fluid volume using ultrasonography in infants. Methods: This prospective observational study enrolled 200 infants (≤12 months) undergoing general anaesthesia. After anaesthetic induction, while preserving spontaneous respiration, we measured gastric antral cross-sectional area using ultrasonography in both the supine and right lateral decubitus positions. We then suctioned the gastric content and measured its volume. The primary outcome was development of a gastric fluid volume prediction model with multiple regression analysis. Agreement between the predicted volume and the suctioned volume was evaluated using a Bland–Altman plot. Results: Overall, 192 infants were included in the final analysis. Pearson correlation analysis showed that the gastric antral cross-sectional area in the supine ( P <0.001; correlation coefficient: 0.667) and right lateral decubitus ( P <0.001; correlation coefficient: 0.845) positions and qualitative antral grade ( P <0.001; correlation coefficient: 0.581) correlated with suctioned volume. We developed a predictive model: predicted volume (ml)=–3.7+6.5 × (right lateral decubitus cross-sectional area [cm 2 ])–3.9 (supine cross-sectional area [cm 2 ])+1.7 × grade ( P <0.01). When comparing theAbstract: Background: Point-of-care ultrasonography can estimate gastric contents and volume to assess the risk of pulmonary aspiration; however, its use in infants has not been well validated. We aimed to develop a predictive model for estimating gastric fluid volume using ultrasonography in infants. Methods: This prospective observational study enrolled 200 infants (≤12 months) undergoing general anaesthesia. After anaesthetic induction, while preserving spontaneous respiration, we measured gastric antral cross-sectional area using ultrasonography in both the supine and right lateral decubitus positions. We then suctioned the gastric content and measured its volume. The primary outcome was development of a gastric fluid volume prediction model with multiple regression analysis. Agreement between the predicted volume and the suctioned volume was evaluated using a Bland–Altman plot. Results: Overall, 192 infants were included in the final analysis. Pearson correlation analysis showed that the gastric antral cross-sectional area in the supine ( P <0.001; correlation coefficient: 0.667) and right lateral decubitus ( P <0.001; correlation coefficient: 0.845) positions and qualitative antral grade ( P <0.001; correlation coefficient: 0.581) correlated with suctioned volume. We developed a predictive model: predicted volume (ml)=–3.7+6.5 × (right lateral decubitus cross-sectional area [cm 2 ])–3.9 (supine cross-sectional area [cm 2 ])+1.7 × grade ( P <0.01). When comparing the predicted volume and suctioned volume, the mean bias was 0.01 ml kg −1 and the limit of agreement was –0.58 to 0.62 ml kg −1 . Conclusions: Gastric fluid volume can be estimated using a predictive model based on ultrasonography data in infants. Clinical trial registration: NCT03155776. … (more)
- Is Part Of:
- British journal of anaesthesia. Volume 127:Number 2(2021)
- Journal:
- British journal of anaesthesia
- Issue:
- Volume 127:Number 2(2021)
- Issue Display:
- Volume 127, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 127
- Issue:
- 2
- Issue Sort Value:
- 2021-0127-0002-0000
- Page Start:
- 275
- Page End:
- 280
- Publication Date:
- 2021-08
- Subjects:
- aspiration -- gastric volume -- infants -- paediatric anaesthesia -- ultrasonography
Anesthesiology -- Periodicals
Anesthesia -- Periodicals
617.9605 - Journal URLs:
- http://bja.oupjournals.org ↗
http://bja.oxfordjournals.org ↗
https://www.journals.elsevier.com/british-journal-of-anaesthesia ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.bja.2021.03.039 ↗
- Languages:
- English
- ISSNs:
- 0007-0912
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2303.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17544.xml