Anatomic, computed tomographic, and ultrasonographic assessment of the lymph nodes in presumed healthy adult cats: The head, neck, thorax, and forelimb. Issue 2 (16th March 2021)
- Record Type:
- Journal Article
- Title:
- Anatomic, computed tomographic, and ultrasonographic assessment of the lymph nodes in presumed healthy adult cats: The head, neck, thorax, and forelimb. Issue 2 (16th March 2021)
- Main Title:
- Anatomic, computed tomographic, and ultrasonographic assessment of the lymph nodes in presumed healthy adult cats: The head, neck, thorax, and forelimb
- Authors:
- Tobón Restrepo, Mauricio
Espada, Yvonne
Aguilar, Adrià
Moll, Xavier
Novellas, Rosa - Abstract:
- Abstract: Assessment of the lymph nodes is key in staging cancer patients. Descriptions of normal features of the feline lymph nodes using computed tomography (CT) and ultrasound (US) are limited. A prospective anatomic and comparative imaging study was performed. The frequency of identification and the size of the lymph nodes during gross pathology from 6 feline cadavers were compared to the images of lymph nodes from 30 presumed healthy adult cats obtained by CT and US. Measurements (length, width, and height) were compared among techniques. The CT and US features of the identified lymph nodes were also recorded. The frequency of identification of the lymph centers varied among techniques and individually. The mandibular lymph nodes were identified in 100% of the cadavers and in 100% of the healthy cats using CT and US. The medial retropharyngeal lymph nodes were identified in 100% of the cats using CT and US. The deep cervical lymph nodes were not visualized in the cadavers. The cranial mediastinal and tracheobronchial lymph nodes were not visualized using US. Lymph nodes showed a higher length on CT and higher width on US. The height was the most statistically significant variable measurement among techniques. On CT, lymph nodes were most frequently isoattenuating or slightly hypoattenuating to surrounding musculature, with homogeneous contrast enhancement. On US, most lymph nodes were isoechoic or hypoechoic to surrounding fat tissue. The lymph nodes were mostAbstract: Assessment of the lymph nodes is key in staging cancer patients. Descriptions of normal features of the feline lymph nodes using computed tomography (CT) and ultrasound (US) are limited. A prospective anatomic and comparative imaging study was performed. The frequency of identification and the size of the lymph nodes during gross pathology from 6 feline cadavers were compared to the images of lymph nodes from 30 presumed healthy adult cats obtained by CT and US. Measurements (length, width, and height) were compared among techniques. The CT and US features of the identified lymph nodes were also recorded. The frequency of identification of the lymph centers varied among techniques and individually. The mandibular lymph nodes were identified in 100% of the cadavers and in 100% of the healthy cats using CT and US. The medial retropharyngeal lymph nodes were identified in 100% of the cats using CT and US. The deep cervical lymph nodes were not visualized in the cadavers. The cranial mediastinal and tracheobronchial lymph nodes were not visualized using US. Lymph nodes showed a higher length on CT and higher width on US. The height was the most statistically significant variable measurement among techniques. On CT, lymph nodes were most frequently isoattenuating or slightly hypoattenuating to surrounding musculature, with homogeneous contrast enhancement. On US, most lymph nodes were isoechoic or hypoechoic to surrounding fat tissue. The lymph nodes were most frequently elongated or rounded. Abstract : CT shows a superior frequency of identification of lymph nodes in adult cats. Lymph nodes were longer on CT but thicker on US. The height was the most statistically significant variable measurement among techniques. On CT, lymph nodes were isoattenuating to surrounding musculature, with homogeneous contrast enhancement. On US, lymph nodes were isoechoic or hypoechoic to surrounding fat. The lymph nodes were elongated or rounded. … (more)
- Is Part Of:
- Journal of anatomy. Volume 239:Issue 2(2021)
- Journal:
- Journal of anatomy
- Issue:
- Volume 239:Issue 2(2021)
- Issue Display:
- Volume 239, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 239
- Issue:
- 2
- Issue Sort Value:
- 2021-0239-0002-0000
- Page Start:
- 264
- Page End:
- 281
- Publication Date:
- 2021-03-16
- Subjects:
- computed tomography -- diagnostic imaging -- feline -- gross anatomy -- lymph node -- ultrasound
Anatomy -- Periodicals
571.3 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1469-7580 ↗
http://www.blackwellpublishing.com/journal.asp?ref=0021-8782&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/joa.13429 ↗
- Languages:
- English
- ISSNs:
- 0021-8782
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4929.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17548.xml