Noncontrast‐Enhanced MR‐Based Conductivity Imaging for Breast Cancer Detection and Lesion Differentiation. Issue 2 (24th April 2021)
- Record Type:
- Journal Article
- Title:
- Noncontrast‐Enhanced MR‐Based Conductivity Imaging for Breast Cancer Detection and Lesion Differentiation. Issue 2 (24th April 2021)
- Main Title:
- Noncontrast‐Enhanced MR‐Based Conductivity Imaging for Breast Cancer Detection and Lesion Differentiation
- Authors:
- Suh, June
Kim, Jun‐Hyeong
Kim, Soo‐Yeon
Cho, Nariya
Kim, Dong‐Hyun
Kim, Rihyeon
Kim, Eun Sil
Jang, Myoung‐jin
Ha, Su Min
Lee, Su Hyun
Chang, Jung Min
Moon, Woo Kyung - Abstract:
- Abstract : Background: There is increasing interest in noncontrast‐enhanced MRI due to safety concerns for gadolinium contrast agents. Purpose: To investigate the clinical feasibility of MR‐based conductivity imaging for breast cancer detection and lesion differentiation. Study Type: Prospective. Subjects: One hundred and ten women, with 112 known cancers and 17 benign lesions (biopsy‐proven), scheduled for preoperative MRI. Field Strength/Sequence: Non‐fat‐suppressed T2‐weighted turbo spin‐echo sequence (T2WI), dynamic contrast‐enhanced MRI and diffusion‐weighted imaging (DWI) at 3T. Assessment: Cancer detectability on each imaging modality was qualitatively evaluated on a per‐breast basis: the conductivity maps derived from T2WI were independently reviewed by three radiologists (R1–R3). T2WI, DWI, and pre‐operative digital mammography were independently reviewed by three other radiologists (R4–R6). Conductivity and apparent diffusion coefficient (ADC) measurements (mean, minimum, and maximum) were performed for 112 cancers and 17 benign lesions independently by two radiologists (R1 and R2). Tumor size was measured from surgical specimens. Statistical Tests: Cancer detection rates were compared using generalized estimating equations. Multivariable logistic regression analysis was performed to identify factors associated with cancer detectability. Discriminating ability of conductivity and ADC was evaluated by using the areas under the receiver operating characteristic curveAbstract : Background: There is increasing interest in noncontrast‐enhanced MRI due to safety concerns for gadolinium contrast agents. Purpose: To investigate the clinical feasibility of MR‐based conductivity imaging for breast cancer detection and lesion differentiation. Study Type: Prospective. Subjects: One hundred and ten women, with 112 known cancers and 17 benign lesions (biopsy‐proven), scheduled for preoperative MRI. Field Strength/Sequence: Non‐fat‐suppressed T2‐weighted turbo spin‐echo sequence (T2WI), dynamic contrast‐enhanced MRI and diffusion‐weighted imaging (DWI) at 3T. Assessment: Cancer detectability on each imaging modality was qualitatively evaluated on a per‐breast basis: the conductivity maps derived from T2WI were independently reviewed by three radiologists (R1–R3). T2WI, DWI, and pre‐operative digital mammography were independently reviewed by three other radiologists (R4–R6). Conductivity and apparent diffusion coefficient (ADC) measurements (mean, minimum, and maximum) were performed for 112 cancers and 17 benign lesions independently by two radiologists (R1 and R2). Tumor size was measured from surgical specimens. Statistical Tests: Cancer detection rates were compared using generalized estimating equations. Multivariable logistic regression analysis was performed to identify factors associated with cancer detectability. Discriminating ability of conductivity and ADC was evaluated by using the areas under the receiver operating characteristic curve (AUC). Results: Conductivity imaging showed lower cancer detection rates (20%–32%) compared to T2WI (62%–71%), DWI (85%–90%), and mammography (79%–88%) (all P < 0.05). Fatty breast on MRI (odds ratio = 11.8, P < 0.05) and invasive tumor size (odds ratio = 1.7, P < 0.05) were associated with cancer detectability of conductivity imaging. The maximum conductivity showed comparable ability to the mean ADC in discriminating between cancers and benign lesions (AUC = 0.67 [95% CI: 0.59, 0.75] vs. 0.84 [0.76, 0.90], P = 0.06 (R1); 0.65 [0.56, 0.73] vs. 0.82 [0.74, 0.88], P = 0.07 (R2)). Data Conclusion: Although conductivity imaging showed suboptimal performance in breast cancer detection, the quantitative measurement of conductivity showed the potential for lesion differentiation. Evidence Level: 1 Technical Efficacy: Stage 2 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 54:Issue 2(2021)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 54:Issue 2(2021)
- Issue Display:
- Volume 54, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 54
- Issue:
- 2
- Issue Sort Value:
- 2021-0054-0002-0000
- Page Start:
- 631
- Page End:
- 645
- Publication Date:
- 2021-04-24
- Subjects:
- electric conductivity -- breast cancer -- noncontrast‐enhanced MRI -- diffusion‐weighted imaging -- apparent diffusion coefficient
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.27655 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17547.xml