Evaluation of a new point-of-care testing for creatinine and urea measurement. (1st July 2021)
- Record Type:
- Journal Article
- Title:
- Evaluation of a new point-of-care testing for creatinine and urea measurement. (1st July 2021)
- Main Title:
- Evaluation of a new point-of-care testing for creatinine and urea measurement
- Authors:
- Bargnoux, Anne-Sophie
Kuster, Nils
Sutra, Thibault
Laroche, Laëtitia
Rodriguez, Annie
Morena, Marion
Chenine, Leila
Chalabi, Lotfi
Dupuy, Anne-Marie
Badiou, Stéphanie
Cristol, Jean-Paul - Abstract:
- Abstract: Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer (ABL90) by adding urea and creatinine. The aim of this study was to verify the performance of these new parameters. This included assessment of imprecision, linearity, accuracy by comparison with central laboratory standard assays and interferences. In addition, clinical utility in a dialysis center was evaluated. Within-lab coefficients of variation were close to 2%. The mean and limits of agreement (mean ± 1.96 SD) of the difference between ABL90 and Roche enzymatic assays on cobas 8000 were 0.5 (from −1.4 to 2.3) mmol/L and −0.9 (from −19.5 to 17.8) µmol/L for urea and creatinine, respectively. The ABL90 enzymatic urea and creatinine assays met the acceptance criteria based on biological variation for imprecision and showed good agreement with central laboratory. The two assays were unaffected by hematocrit variation between 20 and 70%, hemolysis and icterus interferences. It should be noted that the relationship between lab methods and ABL90 was conserved even for high pre-dialysis values allowing easy access to dialysis adequacy parameters ( Kt / V ) and muscle mass evaluation (creatinine index). Rapid measurement of creatinine and urea using whole blood specimens on ABL90 appears as a fast and convenient method. Analytical performances were in accordance with ourAbstract: Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer (ABL90) by adding urea and creatinine. The aim of this study was to verify the performance of these new parameters. This included assessment of imprecision, linearity, accuracy by comparison with central laboratory standard assays and interferences. In addition, clinical utility in a dialysis center was evaluated. Within-lab coefficients of variation were close to 2%. The mean and limits of agreement (mean ± 1.96 SD) of the difference between ABL90 and Roche enzymatic assays on cobas 8000 were 0.5 (from −1.4 to 2.3) mmol/L and −0.9 (from −19.5 to 17.8) µmol/L for urea and creatinine, respectively. The ABL90 enzymatic urea and creatinine assays met the acceptance criteria based on biological variation for imprecision and showed good agreement with central laboratory. The two assays were unaffected by hematocrit variation between 20 and 70%, hemolysis and icterus interferences. It should be noted that the relationship between lab methods and ABL90 was conserved even for high pre-dialysis values allowing easy access to dialysis adequacy parameters ( Kt / V ) and muscle mass evaluation (creatinine index). Rapid measurement of creatinine and urea using whole blood specimens on ABL90 appears as a fast and convenient method. Analytical performances were in accordance with our expectations without any significant interferences by hemolysis or icterus. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 81:Number 4(2021)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 81:Number 4(2021)
- Issue Display:
- Volume 81, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 81
- Issue:
- 4
- Issue Sort Value:
- 2021-0081-0004-0000
- Page Start:
- 290
- Page End:
- 297
- Publication Date:
- 2021-07-01
- Subjects:
- Creatinine -- urea -- interferences -- point-of-care testing -- analytical performances
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2021.1914344 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17529.xml