Iterative navigation of multipole diagnostic catheters to locate repeating‐pattern atrial fibrillation drivers. (11th February 2019)
- Record Type:
- Journal Article
- Title:
- Iterative navigation of multipole diagnostic catheters to locate repeating‐pattern atrial fibrillation drivers. (11th February 2019)
- Main Title:
- Iterative navigation of multipole diagnostic catheters to locate repeating‐pattern atrial fibrillation drivers
- Authors:
- Ganesan, Prasanth
Salmin, Anthony
Cherry, Elizabeth M.
Huang, David T.
Pertsov, Arkady M.
Ghoraani, Behnaz - Abstract:
- Abstract: Introduction: Targeting repeating‐pattern atrial fibrillation (AF) sources (reentry or focal drivers) can help in patient‐specific ablation therapy for AF; however, the development of reliable and accurate tools for locating such sources remains a major challenge. We describe iterative catheter navigation (ICAN) algorithm to locate AF drivers using a conventional circular Lasso catheter. Methods and Results: At each step, the algorithm analyzes 10 bipolar electrograms recoded at a given catheter location and the history of previous catheter movements to determine if the source is inside the catheter loop. If not, it calculates new coordinates and selects a new position for the catheter. The process continues until a source is located. The algorithm was evaluated in a computer model of atrial tissue with various degrees of fibrosis under a broad range of arrhythmia scenarios. The latter included slow and fast reentry, macroreentry, figure‐of‐eight reentry, and fibrillatory conduction. Depending on the initial distance of the catheter from the source and scenario, it took about 3 to 16 steps to localize an AF source. In 94% of cases, the identified location was within 4 mm from the source, independently of the initial position of the catheter. The algorithm worked equally well in the presence of patchy fibrosis, low‐voltage areas, fragmented electrograms, and dominant‐frequency gradients. Conclusions: AF repeating‐pattern sources can be localized using circularAbstract: Introduction: Targeting repeating‐pattern atrial fibrillation (AF) sources (reentry or focal drivers) can help in patient‐specific ablation therapy for AF; however, the development of reliable and accurate tools for locating such sources remains a major challenge. We describe iterative catheter navigation (ICAN) algorithm to locate AF drivers using a conventional circular Lasso catheter. Methods and Results: At each step, the algorithm analyzes 10 bipolar electrograms recoded at a given catheter location and the history of previous catheter movements to determine if the source is inside the catheter loop. If not, it calculates new coordinates and selects a new position for the catheter. The process continues until a source is located. The algorithm was evaluated in a computer model of atrial tissue with various degrees of fibrosis under a broad range of arrhythmia scenarios. The latter included slow and fast reentry, macroreentry, figure‐of‐eight reentry, and fibrillatory conduction. Depending on the initial distance of the catheter from the source and scenario, it took about 3 to 16 steps to localize an AF source. In 94% of cases, the identified location was within 4 mm from the source, independently of the initial position of the catheter. The algorithm worked equally well in the presence of patchy fibrosis, low‐voltage areas, fragmented electrograms, and dominant‐frequency gradients. Conclusions: AF repeating‐pattern sources can be localized using circular catheters without the need to map the entire tissue. The proposed algorithm has the potential to become a useful tool for patient‐specific ablation of AF sources located outside the pulmonary veins. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 5(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 5(2019)
- Issue Display:
- Volume 30, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2019-0030-0005-0000
- Page Start:
- 758
- Page End:
- 768
- Publication Date:
- 2019-02-11
- Subjects:
- atrial fibrillation (AF) -- atrial fibrillation ablation -- multipolar diagnostic catheter -- nonpulmonary‐vein sources -- repeating‐pattern AF source detection
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13872 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17491.xml