Fast iterative pre‐emphasis calibration method enabling third‐order dynamic shim updated fMRI. Issue 3 (7th May 2015)
- Record Type:
- Journal Article
- Title:
- Fast iterative pre‐emphasis calibration method enabling third‐order dynamic shim updated fMRI. Issue 3 (7th May 2015)
- Main Title:
- Fast iterative pre‐emphasis calibration method enabling third‐order dynamic shim updated fMRI
- Authors:
- Fillmer, Ariane
Vannesjo, Signe Johanna
Pavan, Matteo
Scheidegger, Milan
Pruessmann, Klaas Paul
Henning, Anke - Abstract:
- Abstract : Purpose: To calibrate a pre‐emphasis to sufficiently compensate eddy currents for application of dynamic shim updating to fMRI without extension of scan times. Methods: Eddy current effects induced into all shim terms up to third‐order were characterized by spatiotemporal field monitoring, using a third‐order field camera. Pre‐emphasis settings were derived from the measurements and iteratively evaluated and refined. The calibrated pre‐emphasis was applied to slice‐wise dynamic shim updating in combination with a dynamic excitation frequency (F0) determination and a slice‐wise B 0 optimization routine for in vivo echo planar imaging and resting‐state functional MRI. Results: The described method for pre‐emphasis calibration led to settling times of remaining eddy current effects below 2 ms, allowing for the application of dynamic shim updating to fMRI without extension of scan times or induction of eddy current related artifacts. A dynamic F0 determination compensates frequency shifts induced by the superposition of different shim fields, and therefore, prevents an image shift within the field of view. Hardware limitations necessitate the reduction of the maximum applicable B 0 shim field amplitudes and restrict the shim performance. Conclusion: The proposed method enables accurate pre‐emphasis calibration, and therefore, the application of dynamic shim updating to fMRI. Magn Reson Med 75:1119–1131, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 3(2016:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 3(2016:Mar.)
- Issue Display:
- Volume 75, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 3
- Issue Sort Value:
- 2016-0075-0003-0000
- Page Start:
- 1119
- Page End:
- 1131
- Publication Date:
- 2015-05-07
- Subjects:
- B0 shimming -- dynamic shim updating -- spatio‐temporal field monitoring -- pre‐emphasis calibration -- eddy current compensation -- resting‐state fMRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25695 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17502.xml