True constructive interference in the steady state (trueCISS). Issue 4 (24th July 2017)
- Record Type:
- Journal Article
- Title:
- True constructive interference in the steady state (trueCISS). Issue 4 (24th July 2017)
- Main Title:
- True constructive interference in the steady state (trueCISS)
- Authors:
- Hilbert, Tom
Nguyen, Damien
Thiran, Jean‐Philippe
Krueger, Gunnar
Kober, Tobias
Bieri, Oliver - Abstract:
- Abstract : Purpose: To introduce a novel time‐efficient method, termed true constructive interference in the steady state (trueCISS), that not only solves the problem of banding artifacts for balanced steady‐state free precession (bSSFP) but also provides its genuine, that is, true, on‐resonant signal. Methods: After a compressed sensing reconstruction from a set of highly undersampled phase‐cycled bSSFP scans, the local off‐resonance, relaxation time ratio, and equilibrium magnetization are voxel‐wise estimated using a dictionary‐based fitting routine. Subsequently, on‐resonant bSSFP images are generated using the previously estimated parameters. Due to the high undersampling factors used, the acquisition time is not prolonged with respect to a standard CISS acquisition. Results: From a set of 16 phase‐cycled SSFP scans in combination with an eightfold undersampling, both phantom and in vivo whole‐brain experiments demonstrate that banding successfully can be removed. Additionally, trueCISS allows the derivation of synthetic bSSFP images with arbitrary flip angles, which enables image contrasts that may not be possible to acquire in practice due to safety constraints. Conclusion: TrueCISS offers banding‐free bSSFP images with on‐resonant signal intensity and without requiring additional acquisition time compared to conventional methods. Magn Reson Med 79:1901–1910, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 4(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 4(2018)
- Issue Display:
- Volume 79, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 4
- Issue Sort Value:
- 2018-0079-0004-0000
- Page Start:
- 1901
- Page End:
- 1910
- Publication Date:
- 2017-07-24
- Subjects:
- balanced steady‐state free precession -- SSFP -- sparse sampling -- compressed sensing -- iterative reconstruction -- phase cycling
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26836 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17480.xml