13C MRS of human brain at 7 Tesla using [2‐13C]glucose infusion and low power broadband stochastic proton decoupling. Issue 3 (27th April 2015)
- Record Type:
- Journal Article
- Title:
- 13C MRS of human brain at 7 Tesla using [2‐13C]glucose infusion and low power broadband stochastic proton decoupling. Issue 3 (27th April 2015)
- Main Title:
- 13C MRS of human brain at 7 Tesla using [2‐13C]glucose infusion and low power broadband stochastic proton decoupling
- Authors:
- Li, Shizhe
An, Li
Yu, Shao
Ferraris Araneta, Maria
Johnson, Christopher S.
Wang, Shumin
Shen, Jun - Abstract:
- Abstract : Purpose: Carbon‐13 ( 13 C) MR spectroscopy (MRS) of the human brain at 7 Tesla (T) may pose patient safety issues due to high radiofrequency (RF) power deposition for proton decoupling. The purpose of present work is to study the feasibility of in vivo 13 C MRS of human brain at 7 T using broadband low RF power proton decoupling. Methods: Carboxylic/amide 13 C MRS of human brain by broadband stochastic proton decoupling was demonstrated on a 7 T scanner. RF safety was evaluated using the finite‐difference time‐domain method. 13 C signal enhancement by nuclear Overhauser effect (NOE) and proton decoupling was evaluated in both phantoms and in vivo. Results: At 7 T, the peak amplitude of carboxylic/amide 13 C signals was increased by a factor of greater than 4 due to the combined effects of NOE and proton decoupling. The 7 T 13 C MRS technique used decoupling power and average transmit power of less than 35 watts (W) and 3.6 W, respectively. Conclusion: In vivo 13 C MRS studies of human brain can be performed at 7 T, well below the RF safety threshold, by detecting carboxylic/amide carbons with broadband stochastic proton decoupling. Magn Reson Med 75:954–961, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 3(2016:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 3(2016:Mar.)
- Issue Display:
- Volume 75, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 3
- Issue Sort Value:
- 2016-0075-0003-0000
- Page Start:
- 954
- Page End:
- 961
- Publication Date:
- 2015-04-27
- Subjects:
- 13C MRS -- human brain -- stochastic decoupling -- 7 T
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25721 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17488.xml