Comparison of Superb Microvascular Imaging With Color Flow and Power Doppler Imaging of Small Hepatocellular Carcinomas. (23rd April 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of Superb Microvascular Imaging With Color Flow and Power Doppler Imaging of Small Hepatocellular Carcinomas. (23rd April 2018)
- Main Title:
- Comparison of Superb Microvascular Imaging With Color Flow and Power Doppler Imaging of Small Hepatocellular Carcinomas
- Authors:
- Dubinsky, Theodore J.
Revels, Jonathan
Wang, Sherry
Toia, Giuseppe
Sonneborn, Rachelle
Hippe, Daniel S.
Erpelding, Todd - Abstract:
- Abstract : Objectives: The purpose of this study was to compare Superb Microvascular Imaging (SMI; Toshiba America Medical Systems, Tustin, CA) with conventional color flow Doppler (CFD) and power Doppler (PD) imaging in the liver to distinguish between malignant and benign liver neoplasms. Methods: After Institutional Review Board approval (number 449984‐ED), patients undergoing routine pre–radiofrequency ablation planning ultrasound examinations for suspected hepatocellular carcinomas (HCCs) of less than 2 cm in diameter between January 1, 2015, and July 1, 2016, were prospectively identified. Four readers reviewed the ultrasound images independently for the presence or absence of flow centrally and along the periphery of the lesion. Results: Higher peripheral vessel grades were found on SMI than CFD ( P < .001) and PD ( P < .001) imaging: in particular, more grade 2 (39% versus 16% and 11%, respectively) and grade 3 (8% versus 0% and 0%). Overall, more central and peripheral vessels were found on SMI than CFD and PD imaging for both HCC lesions ( P < .001) and benign lesions ( P < .001). Vascular grades were significantly higher in HCC lesions than benign lesions in nearly all cases, although the corresponding area under the curve values were relatively low, at 0.54 to 0.59 for the central vessel grades and 0.63 to 0.64 for the peripheral vessel grades. Conclusions: More central and peripheral vessels were found around liver lesions on SMI than on CFD and PD imaging.Abstract : Objectives: The purpose of this study was to compare Superb Microvascular Imaging (SMI; Toshiba America Medical Systems, Tustin, CA) with conventional color flow Doppler (CFD) and power Doppler (PD) imaging in the liver to distinguish between malignant and benign liver neoplasms. Methods: After Institutional Review Board approval (number 449984‐ED), patients undergoing routine pre–radiofrequency ablation planning ultrasound examinations for suspected hepatocellular carcinomas (HCCs) of less than 2 cm in diameter between January 1, 2015, and July 1, 2016, were prospectively identified. Four readers reviewed the ultrasound images independently for the presence or absence of flow centrally and along the periphery of the lesion. Results: Higher peripheral vessel grades were found on SMI than CFD ( P < .001) and PD ( P < .001) imaging: in particular, more grade 2 (39% versus 16% and 11%, respectively) and grade 3 (8% versus 0% and 0%). Overall, more central and peripheral vessels were found on SMI than CFD and PD imaging for both HCC lesions ( P < .001) and benign lesions ( P < .001). Vascular grades were significantly higher in HCC lesions than benign lesions in nearly all cases, although the corresponding area under the curve values were relatively low, at 0.54 to 0.59 for the central vessel grades and 0.63 to 0.64 for the peripheral vessel grades. Conclusions: More central and peripheral vessels were found around liver lesions on SMI than on CFD and PD imaging. Although there was significantly more vascularity on the periphery of malignant liver lesions than benign lesions, the overall diagnostic performance based on this criterion alone was relatively low, with an area under the curve of 0.64. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 37:Number 12(2018)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 37:Number 12(2018)
- Issue Display:
- Volume 37, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 12
- Issue Sort Value:
- 2018-0037-0012-0000
- Page Start:
- 2915
- Page End:
- 2924
- Publication Date:
- 2018-04-23
- Subjects:
- color flow/power Doppler imaging -- hepatocellular carcinoma -- liver -- superb microvascular imaging
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.14654 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17468.xml