Comparisons between impedance-based and time-based switching bipolar radiofrequency ablation for the treatment of liver cancer. (July 2021)
- Record Type:
- Journal Article
- Title:
- Comparisons between impedance-based and time-based switching bipolar radiofrequency ablation for the treatment of liver cancer. (July 2021)
- Main Title:
- Comparisons between impedance-based and time-based switching bipolar radiofrequency ablation for the treatment of liver cancer
- Authors:
- Yap, Shelley
Ooi, Ean H.
Foo, Ji J.
Ooi, Ean T. - Abstract:
- Abstract: Switching bipolar radiofrequency ablation (bRFA) is a cancer treatment technique that activates multiple pairs of electrodes alternately based on a predefined criterion. Various criteria can be used to trigger the switch, such as time (ablation duration) and tissue impedance. In a recent study on time-based switching bRFA, it was determined that a shorter switch interval could produce better treatment outcome than when a longer switch interval was used, which reduces tissue charring and roll-off induced cooling. In this study, it was hypothesized that a more efficacious bRFA treatment can be attained by employing impedance-based switching. This is because ablation per pair can be maximized since there will be no interruption to RF energy delivery until roll-off occurs. This was investigated using a two-compartment 3D computational model. Results showed that impedance-based switching bRFA outperformed time-based switching when the switch interval of the latter is 100 s or higher. When compared to the time-based switching with switch interval of 50 s, the impedance-based model is inferior. It remains to be investigated whether the impedance-based protocol is better than the time-based protocol for a switch interval of 50 s due to the inverse relationship between ablation and treatment efficacies. It was suggested that the choice of impedance-based or time-based switching could ultimately be patient-dependent. Graphical abstract: Image 1 Highlights: Impedance-basedAbstract: Switching bipolar radiofrequency ablation (bRFA) is a cancer treatment technique that activates multiple pairs of electrodes alternately based on a predefined criterion. Various criteria can be used to trigger the switch, such as time (ablation duration) and tissue impedance. In a recent study on time-based switching bRFA, it was determined that a shorter switch interval could produce better treatment outcome than when a longer switch interval was used, which reduces tissue charring and roll-off induced cooling. In this study, it was hypothesized that a more efficacious bRFA treatment can be attained by employing impedance-based switching. This is because ablation per pair can be maximized since there will be no interruption to RF energy delivery until roll-off occurs. This was investigated using a two-compartment 3D computational model. Results showed that impedance-based switching bRFA outperformed time-based switching when the switch interval of the latter is 100 s or higher. When compared to the time-based switching with switch interval of 50 s, the impedance-based model is inferior. It remains to be investigated whether the impedance-based protocol is better than the time-based protocol for a switch interval of 50 s due to the inverse relationship between ablation and treatment efficacies. It was suggested that the choice of impedance-based or time-based switching could ultimately be patient-dependent. Graphical abstract: Image 1 Highlights: Impedance-based switching was better than time-based for switch intervals ≥100 s. Impedance-based bRFA deliver lower RF energy to the tissue compared to model s 50 . Coagulation volume obtained using impedance-based bRFA was smaller than model s 50 . Impedance-based bRFA produced higher ablation efficacy than model s 50 . Impedance-based bRFA produced lower treatment efficacy than model s 50 . … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 134(2021)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 134(2021)
- Issue Display:
- Volume 134, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 134
- Issue:
- 2021
- Issue Sort Value:
- 2021-0134-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- bRFA -- Ablation efficacy -- Treatment efficacy -- Thermal coagulation -- Thermal therapy
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2021.104488 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17458.xml