High-resolution CT image analysis based on 3D convolutional neural network can enhance the classification performance of radiologists in classifying pulmonary non-solid nodules. Issue 141 (August 2021)
- Record Type:
- Journal Article
- Title:
- High-resolution CT image analysis based on 3D convolutional neural network can enhance the classification performance of radiologists in classifying pulmonary non-solid nodules. Issue 141 (August 2021)
- Main Title:
- High-resolution CT image analysis based on 3D convolutional neural network can enhance the classification performance of radiologists in classifying pulmonary non-solid nodules
- Authors:
- Zhang, Teng
Wang, Yida
Sun, Yingli
Yuan, Mei
Zhong, Yan
Li, Hai
Yu, Tongfu
Wang, Jie - Abstract:
- Highlights: It is of great importance for radiologists to classify non-solid nodules. Morphological and quantitative parameters were widely accessed but the result varied. CNN showed superiority over radiologists in classifying non-solid nodules. Combining CNN significantly enhanced the classification performance of radiologists. CNN may serve as a vital decision support tool for radiologists to classify non-solid nodules. Abstract: Objective: To investigate whether 3D convolutional neural network (CNN) is able to enhance the classification performance of radiologists in classifying pulmonary non-solid nodules (NSNs). Materials and Methods: Data of patients with solitary NSNs and diagnosed as adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC) in pathological after surgical resection were analyzed retrospectively. Ultimately, 532 patients in our institution were included in the study: 427 cases (144 AIS, 167 MIA, 116 IAC) were assigned to training dataset and 105 cases (36 AIS, 41 MIA and 28 IAC) were assigned to validation dataset. For external validation, 177 patients (60 AIS, 69 MIA and 48 IAC) from another hospital were assigned to testing dataset. The clinical and morphological characteristics of NSNs were established as radiologists' model. The trained classification model based on 3D CNN was used to identify NSNs types automatically. The evaluation and comparison on classification performance of the two models andHighlights: It is of great importance for radiologists to classify non-solid nodules. Morphological and quantitative parameters were widely accessed but the result varied. CNN showed superiority over radiologists in classifying non-solid nodules. Combining CNN significantly enhanced the classification performance of radiologists. CNN may serve as a vital decision support tool for radiologists to classify non-solid nodules. Abstract: Objective: To investigate whether 3D convolutional neural network (CNN) is able to enhance the classification performance of radiologists in classifying pulmonary non-solid nodules (NSNs). Materials and Methods: Data of patients with solitary NSNs and diagnosed as adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC) in pathological after surgical resection were analyzed retrospectively. Ultimately, 532 patients in our institution were included in the study: 427 cases (144 AIS, 167 MIA, 116 IAC) were assigned to training dataset and 105 cases (36 AIS, 41 MIA and 28 IAC) were assigned to validation dataset. For external validation, 177 patients (60 AIS, 69 MIA and 48 IAC) from another hospital were assigned to testing dataset. The clinical and morphological characteristics of NSNs were established as radiologists' model. The trained classification model based on 3D CNN was used to identify NSNs types automatically. The evaluation and comparison on classification performance of the two models and CNN + radiologists' model were performed via receiver operating curve (ROC) analysis and integrated discrimination improvement (IDI) index. The Akaike information criterion (AIC) was calculated to find the best-fit model. Results: In external testing dataset, radiologists' model showed inferior classification performance than CNN model both in discriminating AIS from MIA-IAC and AIS-MIA from IAC (the area under the ROC curve (Az value), 0.693 vs 0.820, P = 0.011; 0.746 vs 0.833, P = 0.026, respectively). However, combining CNN significantly enhanced the classification performance of radiologists and exhibited higher Az values than CNN model alone (Az values, 0.893 vs 0.820, P < 0.001; 0.906 vs 0.833, P < 0.001, respectively). The IDI index further confirmed CNN's contribution to radiologists in classifying NSNs (IDI = 25.8 % (18.3–46.1 %), P < 0.001; IDI = 30.1 % (26.1–45.2 %), P < 0.001, respectively). The CNN + radiologists' model also provided the best fit over radiologists' model and CNN model alone (AIC value 63.3 % vs. 29.5 %, 49.5 %, P < 0.001; 69.2 % vs. 34.9 %, 53.6 %, P < 0.001, respectively). Conclusion: CNN successfully classified NSNs based on CT images and its classification performance were superior to radiologists' model. But the classification performance of radiologists can be significantly enhanced when combined with CNN in classifying NSNs. … (more)
- Is Part Of:
- European journal of radiology. Issue 141(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 141(2021)
- Issue Display:
- Volume 141, Issue 141 (2021)
- Year:
- 2021
- Volume:
- 141
- Issue:
- 141
- Issue Sort Value:
- 2021-0141-0141-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Tomography -- X-ray computed -- Adenocarcinoma of lung -- Neoplasm invasiveness -- Neural networks -- computer
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109810 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17444.xml