Esophageal luminal temperature rise during atrial fibrillation ablation is associated with lower radiofrequency electrode distance and baseline impedance. (28th May 2021)
- Record Type:
- Journal Article
- Title:
- Esophageal luminal temperature rise during atrial fibrillation ablation is associated with lower radiofrequency electrode distance and baseline impedance. (28th May 2021)
- Main Title:
- Esophageal luminal temperature rise during atrial fibrillation ablation is associated with lower radiofrequency electrode distance and baseline impedance
- Authors:
- Khoshknab, Mirmilad
Kuo, Ling
Zghaib, Tarek
Arkles, Jeffrey
Santangeli, Pasquale
Marchlinski, Francis E.
Han, Yuchi
Desjardins, Benoit
Nazarian, Saman - Abstract:
- Abstract: Introduction: Esophageal injury during atrial fibrillation (AF) ablation is a life‐threatening complication. We sought to measure the association of esophageal temperature attenuation with radiofrequency (RF) electrode impedance, contact force, and distance from the esophagus. Methods: The retrospective study cohort included 35 patients with mean age 64 ± 10 years, of whom 74.3% were male, and 40% had persistent AF. All patients had undergone preprocedural cardiac magnetic resonance (CMR) followed by AF ablation with luminal esophageal temperature monitoring. Lesion locations were co‐registered with CMR image segmentations of left atrial and esophageal anatomy. Luminal esophageal temperature, time matched RF lesion data, and ablation distance from the nearest esophageal location were collected as panel data. Results: Luminal esophageal temperature changes corresponding to 3667 distinct lesions, delivered with mean power 27.9 ± 5.5 W over a mean duration of 22.2 ± 10.5 s were analyzed. In multivariable analyses, clustered per patient, examining posterior wall lesions only, and adjusted for lesion power and duration as set by the operator, lesion distance from the esophagus (−0.003°C/mm, p < .001), and baseline impedance (−0.015°C/Ω, p < .001) were associated with changes in luminal esophageal temperature. Conclusion: Esophageal luminal temperature rises are associated with shorter lesion distance from esophagus and lower baseline impedance during RF lesionAbstract: Introduction: Esophageal injury during atrial fibrillation (AF) ablation is a life‐threatening complication. We sought to measure the association of esophageal temperature attenuation with radiofrequency (RF) electrode impedance, contact force, and distance from the esophagus. Methods: The retrospective study cohort included 35 patients with mean age 64 ± 10 years, of whom 74.3% were male, and 40% had persistent AF. All patients had undergone preprocedural cardiac magnetic resonance (CMR) followed by AF ablation with luminal esophageal temperature monitoring. Lesion locations were co‐registered with CMR image segmentations of left atrial and esophageal anatomy. Luminal esophageal temperature, time matched RF lesion data, and ablation distance from the nearest esophageal location were collected as panel data. Results: Luminal esophageal temperature changes corresponding to 3667 distinct lesions, delivered with mean power 27.9 ± 5.5 W over a mean duration of 22.2 ± 10.5 s were analyzed. In multivariable analyses, clustered per patient, examining posterior wall lesions only, and adjusted for lesion power and duration as set by the operator, lesion distance from the esophagus (−0.003°C/mm, p < .001), and baseline impedance (−0.015°C/Ω, p < .001) were associated with changes in luminal esophageal temperature. Conclusion: Esophageal luminal temperature rises are associated with shorter lesion distance from esophagus and lower baseline impedance during RF lesion delivery. When procedural strategy requires RF delivery near the esophagus, selection of sites with higher baseline impedance may improve safety. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 7(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 7(2021)
- Issue Display:
- Volume 32, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2021-0032-0007-0000
- Page Start:
- 1857
- Page End:
- 1864
- Publication Date:
- 2021-05-28
- Subjects:
- atrial fibrillation -- catheter ablation -- electrophysiology -- impedance
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15097 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17444.xml