Measurement of femoral axial offset. Issue 7 (9th September 2020)
- Record Type:
- Journal Article
- Title:
- Measurement of femoral axial offset. Issue 7 (9th September 2020)
- Main Title:
- Measurement of femoral axial offset
- Authors:
- Matsubayashi, Shohei
Isobe, Yuusaku
Chiba, Ko
Tsujimoto, Ritsu
Osaki, Makoto
Imamura, Takeshi
Tsurumoto, Toshiyuki - Abstract:
- Abstract: Purpose to examine the accuracy and reproducibility of the femoral axial offset measured from the retrocondylar plane by computed tomography (CT). Bone specimens of the femur of 15 males and 15 females were analyzed. CT imaging was performed and data of the coordinates were collected (center of femoral head, center of an ellipse around greater trochanter, center of an ellipse around the base of femoral neck, posterior edge of great trochanter, and both posterior condyles). The angle between the line connecting center of the femoral head and center of an ellipse around greater trochanter and the line connecting both posterior condyles was set as anteversion 1. The angle between the line connecting the center of femoral head and center of an ellipse around base of the femoral neck and the line connecting both posterior condyles was set as anteversion 2. The femoral axial offset was measured from the retrocondylar plane. Measurements were performed three times on the same subject, and intrarater reliability (ICC) was determined. In addition, interrater reliability (ICC) was determined by comparing data from three raters. The mean value for anteversion 1 was 20.1° for males and 22.7° for females. The values for anteversion 2 were 16.0° and 19.9° for males and females, respectively. Offset was 34.0 and 33.4 mm in males and females, respectively. Intrarater ICC and interrater ICC exceeded 0.81 for both methods, suggesting that the method of measurement was reliable.Abstract: Purpose to examine the accuracy and reproducibility of the femoral axial offset measured from the retrocondylar plane by computed tomography (CT). Bone specimens of the femur of 15 males and 15 females were analyzed. CT imaging was performed and data of the coordinates were collected (center of femoral head, center of an ellipse around greater trochanter, center of an ellipse around the base of femoral neck, posterior edge of great trochanter, and both posterior condyles). The angle between the line connecting center of the femoral head and center of an ellipse around greater trochanter and the line connecting both posterior condyles was set as anteversion 1. The angle between the line connecting the center of femoral head and center of an ellipse around base of the femoral neck and the line connecting both posterior condyles was set as anteversion 2. The femoral axial offset was measured from the retrocondylar plane. Measurements were performed three times on the same subject, and intrarater reliability (ICC) was determined. In addition, interrater reliability (ICC) was determined by comparing data from three raters. The mean value for anteversion 1 was 20.1° for males and 22.7° for females. The values for anteversion 2 were 16.0° and 19.9° for males and females, respectively. Offset was 34.0 and 33.4 mm in males and females, respectively. Intrarater ICC and interrater ICC exceeded 0.81 for both methods, suggesting that the method of measurement was reliable. Accuracy and reproducibility of the measurement of femoral axial offset from the retrocondylar plane were high. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 39:Issue 7(2021)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 39:Issue 7(2021)
- Issue Display:
- Volume 39, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 39
- Issue:
- 7
- Issue Sort Value:
- 2021-0039-0007-0000
- Page Start:
- 1383
- Page End:
- 1389
- Publication Date:
- 2020-09-09
- Subjects:
- bone -- hip
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.24843 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17440.xml